Literature DB >> 15957630

Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications.

Tryggve Hemmingsson1, Dag Linnarsson, Rudolf Gambert.   

Abstract

Changes in expired nitric oxide (NO) occur in airway inflammation and have proved to be important in the monitoring of inflammatory disease processes such as asthma. We set out to develop a novel hand-held NO-analyzer with a performance comparable to the present more costly and complex chemiluminescence instruments. The new device is based on a specially designed electrochemical sensor, where we have developed a novel sampling and analysis technology, compensating for the relatively slow response properties of the electrochemical sensor technique. A Lowest Detection Limit in NO-analysis from reference gas tests of less than 3 ppb and a response time of 15 seconds together with an average precision in human breath measurements of 1.4 ppb were obtained. We also show an agreement with the existing 'gold standard' FENO measurement technique, within 0.5 ppb in a group of 19 subjects together with a high linearity and accuracy compared to reference gases. The new analyzer enables affordable monitoring of inflammatory airway diseases in research and routine clinical practice.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15957630     DOI: 10.1007/s10877-005-1158-z

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  12 in total

1.  Recommendations for standardized procedures for the on-line and off-line measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide in adults and children-1999. This official statement of the American Thoracic Society was adopted by the ATS Board of Directors, July 1999.

Authors: 
Journal:  Am J Respir Crit Care Med       Date:  1999-12       Impact factor: 21.405

2.  Reproducibility of exhaled nitric oxide measurements in healthy and asthmatic adults and children.

Authors:  S A Kharitonov; F Gonio; C Kelly; S Meah; P J Barnes
Journal:  Eur Respir J       Date:  2003-03       Impact factor: 16.671

3.  Diagnosing asthma: comparisons between exhaled nitric oxide measurements and conventional tests.

Authors:  Andrew D Smith; Jan O Cowan; Sue Filsell; Chris McLachlan; Gabrielle Monti-Sheehan; Pamela Jackson; D Robin Taylor
Journal:  Am J Respir Crit Care Med       Date:  2003-11-25       Impact factor: 21.405

4.  Endogenous nitric oxide is present in the exhaled air of rabbits, guinea pigs and humans.

Authors:  L E Gustafsson; A M Leone; M G Persson; N P Wiklund; S Moncada
Journal:  Biochem Biophys Res Commun       Date:  1991-12-16       Impact factor: 3.575

5.  Effect of atmospheric nitric oxide (NO) on measurements of exhaled NO in asthmatic children.

Authors:  E Baraldi; N M Azzolin; C Dario; S Carra; R Ongaro; P Biban; F Zacchello
Journal:  Pediatr Pulmonol       Date:  1998-07

6.  Marked flow-dependence of exhaled nitric oxide using a new technique to exclude nasal nitric oxide.

Authors:  P E Silkoff; P A McClean; A S Slutsky; H G Furlott; E Hoffstein; S Wakita; K R Chapman; J P Szalai; N Zamel
Journal:  Am J Respir Crit Care Med       Date:  1997-01       Impact factor: 21.405

7.  Quantitative analysis of urine vapor and breath by gas-liquid partition chromatography.

Authors:  L Pauling; A B Robinson; R Teranishi; P Cary
Journal:  Proc Natl Acad Sci U S A       Date:  1971-10       Impact factor: 11.205

8.  Relationship between exhaled nitric oxide and mucosal eosinophilic inflammation in children with difficult asthma, after treatment with oral prednisolone.

Authors:  D N Payne; I M Adcock; N M Wilson; T Oates; M Scallan; A Bush
Journal:  Am J Respir Crit Care Med       Date:  2001-10-15       Impact factor: 21.405

9.  Exhaled nitric oxide correlates with airway eosinophils in childhood asthma.

Authors:  T J Warke; P S Fitch; V Brown; R Taylor; J D M Lyons; M Ennis; M D Shields
Journal:  Thorax       Date:  2002-05       Impact factor: 9.139

10.  Increased amount of nitric oxide in exhaled air of asthmatics.

Authors:  K Alving; E Weitzberg; J M Lundberg
Journal:  Eur Respir J       Date:  1993-10       Impact factor: 16.671

View more
  9 in total

1.  Correlation of nasal nitric oxide measurement with computed tomography findings in chronic rhinosinusitis.

Authors:  Yogesh G Dabholkar; Akanksha A Saberwal; Haritosh K Velankar; Adip K Shetty; Nilesh P Chordia; Sneha R Budhwani
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2013-11-20

Review 2.  Electrochemical Sensors for Clinic Analysis.

Authors:  You Wang; Hui Xu; Jianming Zhang; Guang Li
Journal:  Sensors (Basel)       Date:  2008-03-27       Impact factor: 3.576

3.  Exhaled nitric oxide decreases after positive food-allergen challenge.

Authors:  Avigael H Benhamou; Alice Koehli; Isabelle Rochat; Demet Inci; Alexander Moeller; Philip Taramarcaz; Roger P Lauener; Philippe A Eigenmann
Journal:  Clin Transl Allergy       Date:  2011-11-28       Impact factor: 5.871

4.  Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.

Authors:  K Alving; C Janson; L Nordvall
Journal:  Respir Res       Date:  2006-04-20

5.  Fractional exhaled nitric oxide: comparison between portable devices and correlation with sputum eosinophils.

Authors:  Sehyo Yune; Jin Young Lee; Dong Chull Choi; Byung Jae Lee
Journal:  Allergy Asthma Immunol Res       Date:  2015-03-05       Impact factor: 5.764

Review 6.  Clinical application of exhaled nitric oxide measurements in a korean population.

Authors:  Woo-Jung Song; Ji-Won Kwon; Eun-Jin Kim; Sang-Min Lee; Sae-Hoon Kim; So-Yeon Lee; Sang-Heon Kim; Heung-Woo Park; Yoon-Seok Chang; Woo Kyung Kim; Jung Yeon Shim; Ju-Hee Seo; Byoung-Ju Kim; Hyo Bin Kim; Dae Jin Song; Gwang Cheon Jang; An-Soo Jang; Jung-Won Park; Ho-Joo Yoon; Joo-Shil Lee; Sang-Heon Cho; Soo-Jong Hong
Journal:  Allergy Asthma Immunol Res       Date:  2014-08-19       Impact factor: 5.764

7.  Significance of Nitric Oxyde Saliva Concentration of the Patients with Renal Failure on Hemodialysis.

Authors:  Marina Vucijak-Grgurevic; Faris Zvizdic; Azra Durak-Nalbantic; Elmedina Jahic; Nerma Resic; Jasminko Huskic
Journal:  Mater Sociomed       Date:  2018-12

8.  Shot-noise limited Faraday rotation spectroscopy for detection of nitric oxide isotopes in breath, urine, and blood.

Authors:  Yin Wang; Michal Nikodem; Eric Zhang; Frank Cikach; Jarrod Barnes; Suzy Comhair; Raed A Dweik; Christina Kao; Gerard Wysocki
Journal:  Sci Rep       Date:  2015-03-13       Impact factor: 4.379

Review 9.  Fractional exhaled nitric oxide-measuring devices: technology update.

Authors:  Mauro Maniscalco; Carolina Vitale; Alessandro Vatrella; Antonio Molino; Andrea Bianco; Gennaro Mazzarella
Journal:  Med Devices (Auckl)       Date:  2016-06-23
  9 in total