Literature DB >> 15955193

Development of implantable devices for continuous ambulatory monitoring of central hemodynamic values in heart failure patients.

Tom Bennett1, Barbro Kjellstrom, Robert Taepke, Lars Ryden.   

Abstract

BACKGROUND: Care and management of patients with congestive heart failure (CHF) is a major health-care challenge. The value of acute hemodynamic data in assessing heart failure has been questioned in some studies, while more intensive hemodynamic monitoring has been reported to improve patient care in others. A series of patient studies are reported here that were conducted to identify device requirements and verify the feasibility of continuous hemodynamic monitoring in CHF patients and devices for remote transfer and use of these data. METHODS AND
RESULTS: The results of four separate studies in 68 CHF patients who received systems for chronic hemodynamic monitoring between 1992 and the present are reviewed. One early study was with five patients followed for 7-16 months and another study was with nine patients followed for 4-22 months. A third study included 21 patients followed up to 39 months, and the fourth study included 32 patients implanted in 1998-99 with many of them still in follow-up. These studies support the technical feasibility of implanted devices and the external instrumentation required to transfer and manage the collected data. They also support the long-term stability and accuracy of these systems. Three additional acute studies conducted with 30 patients and chronic data from 53 of the 68 patients with the implanted systems are presented that support the feature included in the newer monitors--the ability to reliably estimate pulmonary artery diastolic pressures from the right ventricular pressure signal.
CONCLUSIONS: Development of implantable technology to measure several hemodynamic variables in ambulatory CHF patients is feasible. External instrumentation needed to remotely acquire data from the implanted devices has been verified. The potential to eliminate the uncertainties associated with the use of acute, invasive hemodynamics and the ability to evaluate long-term ambulatory hemodynamic patterns is provided. These findings set the stage for determining the potential clinical value of these systems in impacting the care of chronic CHF patients.

Entities:  

Mesh:

Year:  2005        PMID: 15955193     DOI: 10.1111/j.1540-8159.2005.09558.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

Review 1.  Current rare indications and future directions for implantable loop recorders.

Authors:  Simon Wechselberger; Christopher Piorkowski; Matthias Pohl
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-12

2.  Monitoring of heart failure: comparison of left atrial pressure with intrathoracic impedance and natriuretic peptide measurements in an experimental model of ovine heart failure.

Authors:  Miriam T Rademaker; Christopher J Charles; Iain C Melton; A Mark Richards; Christopher M Frampton; Jeff Siou; Fujian Qu; Neal L Eigler; Dan Gutfinger; Richard W Troughton
Journal:  Clin Sci (Lond)       Date:  2011-03       Impact factor: 6.124

3.  Direct left atrial pressure monitoring in severe heart failure: long-term sensor performance.

Authors:  Richard W Troughton; Jay Ritzema; Neal L Eigler; Iain C Melton; Henry Krum; Philip B Adamson; Saibal Kar; Prediman K Shah; James S Whiting; J Thomas Heywood; Spencer Rosero; Jagmeet P Singh; Leslie Saxon; Ray Matthews; Ian G Crozier; William T Abraham
Journal:  J Cardiovasc Transl Res       Date:  2010-10-14       Impact factor: 4.132

4.  Estimation of cardiac output in patients with congestive heart failure by analysis of right ventricular pressure waveforms.

Authors:  Mustafa Karamanoglu; Tom Bennett; Marcus Ståhlberg; Vincent Splett; Barbro Kjellström; Cecilia Linde; Frieder Braunschweig
Journal:  Biomed Eng Online       Date:  2011-05-13       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.