Literature DB >> 15951741

Validation of TONOPORT V blood-pressure measuring monitor in adults.

A Haensel1, K Utech, W Langewitz.   

Abstract

A new automatic blood-pressure (BP) measuring device TONOPORT V was evaluated according to the International Protocol for Validation of Blood Pressure Measuring Devices in adults by the European Society of Hypertension. BP values measured by the TONOPORT V were compared to BP readings from two independent observers. A total of 33 patients (20 males, 13 females) provided systolic and diastolic BP readings in the normotensive, borderline hypertensive, and hypertensive range. Their age varied between 30 and 83 years, and their arm circumference between 23 and 36 cm. The device showed a mean (+/-s.d.) deviation from observer measurements of -0.7 (4.6) mmHg for systolic and -0.8 (4.4) mmHg for diastolic BP. The accuracy of the device did not vary according to BP values or other patient characteristics. The device passed all phases of the protocol and can be recommended following the regulation rules of the European Society of Hypertension.

Entities:  

Mesh:

Year:  2005        PMID: 15951741     DOI: 10.1038/sj.jhh.1001876

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  4 in total

1.  Validation of the TONOPORT VI ambulatory blood pressure monitor in adults according to the European Society of Hypertension International Protocol revision 2010.

Authors:  M Abou-Dakn; C Döhmen; S Wenzel
Journal:  J Hum Hypertens       Date:  2016-07-14       Impact factor: 3.012

2.  Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010.

Authors:  Peter Bramlage; Cornelia Deutsch; Ralf Krüger; Andreas Wolf; Peter Müller; Thomas Zwingers; Beate Beime; Thomas Mengden
Journal:  Vasc Health Risk Manag       Date:  2014-05-13

3.  Prevalence of resistant hypertension and associated factors for blood pressure control status with optimal medical therapy using Korean ambulatory blood pressure monitoring registry data.

Authors:  Sung Il Choi; Soon Kil Kim; Sungha Park; Ju Han Kim; Sang Hyun Ihm; Gwang-Il Kim; Woo Shik Kim; Wook Bum Pyun; Yu-Mi Kim; Jinho Shin
Journal:  Clin Hypertens       Date:  2016-01-27

4.  Height and sex is strongly associated with radial augmentation index in Korean patients with never-treated hypertension.

Authors:  Kye Taek Ahn; Kwang-In Park; Mi Joo Kim; Jin Kyung Oh; Ji Hye Han; Hee Jin Kwon; Seon-Ah Jin; Jun-Hyung Kim; Jae-Hyeong Park; Jae-Hwan Lee; Si Wan Choi; In-Whan Seong; Jin-Ok Jeong
Journal:  Clin Interv Aging       Date:  2016-04-11       Impact factor: 4.458

  4 in total