Literature DB >> 15950846

Cardiac index measurements during rapid preload changes: a comparison of pulmonary artery thermodilution with arterial pulse contour analysis.

Thomas W Felbinger1, Daniel A Reuter, Holger K Eltzschig, Julian Bayerlein, Alwin E Goetz.   

Abstract

STUDY
OBJECTIVE: To compare cardiac index (CI) values obtained by pulmonary artery thermodilution (CIPA), arterial thermodilution (CITD), and arterial pulse contour analysis (CIPC) during rapid fluid administration, as accurate and rapid detection of CI changes is critical during acute preload changes for guiding volume and vasopressor therapy in critically ill patients, and the accuracy of CIPC during acute changes in loading condition is currently unknown.
DESIGN: Prospective clinical study.
SETTING: Cardiac surgical intensive care unit of a university hospital. PATIENTS: Seventeen American Society of Anesthesiologists (ASA) physical status II and III patients, aged 32 to 76 years, with normal left ventricular function during the early postoperative period after elective coronary artery bypass graft surgery. MEASUREMENTS: After baseline determinations of CIPA, CIPC, and CITD were made, fluid loading was performed using 10 mL times body mass index of hydroxyethyl starch 6%. CIPA, CIPC, and CITD were determined, and changes in CI (DeltaCI) were calculated. Fluid load was repeated until no increase in stroke volume index (DeltaSVI <10%) was achieved. MAIN
RESULTS: Regression analysis between CIPA/CIPC, CIPA/CITD, and CIPC/CITD revealed r2 = 0.92, r2 = 0.92, and r2 = 0.98. Regression analysis between DeltaCIPA/DeltaCIPC, DeltaCIPA/DeltaCITD, and DeltaCIPC/DeltaCITD revealed r2 = 0.57, r2 = 0.67, and r2 = 0.74, respectively. Bland-Altman analysis was used to determine accuracy and precision of the 3 methods compared. The mean differences (m) and SD between DeltaCIPA/DeltaCIPC, DeltaCIPA/DeltaCITD, and DeltaCIPC/DeltaCITD resulted in m = -1.01%, SD = 6.51%; m = -0.83%, SD = 5.80%; and m = -0.33%, SD = 4.65%, respectively.
CONCLUSION: Compared with pulmonary artery thermodilution, arterial pulse contour analysis reflects relative changes in CI during rapid changes of preload with clinically acceptable accuracy.

Entities:  

Mesh:

Year:  2005        PMID: 15950846     DOI: 10.1016/j.jclinane.2004.06.013

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  21 in total

Review 1.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

2.  Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability.

Authors:  Anders Johansson; Michelle Chew
Journal:  J Clin Monit Comput       Date:  2007-06-01       Impact factor: 2.502

Review 3.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

4.  Comparison of the accuracy of transpulmonary thermodilution measurement using indicators of different temperatures.

Authors:  Shulan Chen; Pingdong Lin; Zhenshuang Du; Fangchen Lan; Shanshan Wu; Tiegang Zhong; Xiaohua Liang; Hongyu Liu; Cuiping Zeng; Chenghua Zhang
Journal:  Int J Clin Exp Med       Date:  2014-12-15

5.  Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter.

Authors:  Bouchra Lamia; Hyung Kook Kim; Donald A Severyn; Michael R Pinsky
Journal:  J Clin Monit Comput       Date:  2017-02-10       Impact factor: 2.502

Review 6.  The transpulmonary thermodilution technique.

Authors:  Samir G Sakka; Daniel A Reuter; Azriel Perel
Journal:  J Clin Monit Comput       Date:  2012-07-18       Impact factor: 2.502

7.  [Accuracy of pulse contour cardiac index measurements during changes of preload and aortic impedance].

Authors:  T W Felbinger; M S Goepfert; T Goresch; A E Goetz; D A Reuter
Journal:  Anaesthesist       Date:  2005-08       Impact factor: 1.041

8.  Influence of volume administration on Doppler-based renal resistive index, renal hemodynamics and renal function in medical intensive care unit patients with septic-induced acute kidney injury: a pilot study.

Authors:  Tobias Lahmer; Sebastian Rasch; Christopher Schnappauf; Roland M Schmid; Wolfgang Huber
Journal:  Int Urol Nephrol       Date:  2016-05-18       Impact factor: 2.370

9.  Clinical evaluation of the flotrac/Vigileo system for continuous cardiac output monitoring in patients undergoing regional anesthesia for elective cesarean section: a pilot study.

Authors:  José Otavio Costa Auler; Marcelo L A Torres; Mônica M Cardoso; Thais C Tebaldi; André P Schmidt; Mario M Kondo; Marcelo Zugaib
Journal:  Clinics (Sao Paulo)       Date:  2010-06       Impact factor: 2.365

10.  Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices.

Authors:  Xavier Monnet; Nadia Anguel; Brice Naudin; Julien Jabot; Christian Richard; Jean-Louis Teboul
Journal:  Crit Care       Date:  2010-06-10       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.