Abstract

PURPOSE: To determine the efficacy of echography with new generation contrast agents in visualizing vascularization of choroidal malignant melanomas.
METHODS: An echographic contrast medium consisting of phospholipidic microbubbles filled with sulphur hexafluoride (Sonovue) was used to visualize microcirculation in 25 cases of choroidal lesions already diagnosed with standardized echography (21 choroidal malignant melanomas, four disciform lesions).
RESULTS: In untreated malignant melanomas contrast agent echography revealed the presence of a dense microcirculation inside the mass. In one case vitreal seeding of the contrast agent was detectable before enucleation and histological examination revealed the presence of tumoral cells. In 12 cases treated with transpupillary thermotherapy, contrast agent echographic evaluation showed heavy regression of microcirculation after 1 week, confirmed in one case by histology, and a reduction of 70-80% in dimensions after 6 months (which appeared to have stabilized at subsequent examinations). In four cases treated with proton beam brachytherapy 2 years prior to our examination, contrast agent echography showed the absence of a microvascular network and the presence of large vessels and blood lakes. In four cases of disciform lesion, deep and superficial retina-associated vascularization was observed, with a weak spread of contrast agent inside the lesion.
CONCLUSION: Live representation with good resolution of choroidal malignant melanoma microcirculation was obtained.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15948789     DOI: 10.1111/j.1600-0420.2005.00428.x

Source DB:  PubMed          Journal:  Acta Ophthalmol Scand        ISSN: 1395-3907


  3 in total

1.  Application of ultrasound contrast in identification and diagnosis of ocular spaceoccupying lesions.

Authors:  Jia-Ying Yuan; Jian-Hua Zhang; Chong Tang; Jing-Zhi Zhao; Chao Pang; Xin-Chun Ren; Hong Zhu; Yun-Tao Zhang
Journal:  Int J Ophthalmol       Date:  2011-08-18       Impact factor: 1.779

2.  In vivo high-frequency contrast-enhanced ultrasonography of choroidal melanoma in rabbits: imaging features and histopathologic correlations.

Authors:  Shin J Kang; Qing Zhang; Samirkumar R Patel; Damian Berezovsky; Hua Yang; Yanggan Wang; Hans E Grossniklaus
Journal:  Br J Ophthalmol       Date:  2013-05-04       Impact factor: 4.638

3.  Quantitative, noninvasive assessment of intra- and extraocular perfusion by contrast-enhanced ultrasonography and its clinical applicability in healthy dogs.

Authors:  Klaas-Ole Blohm; Katharina M Hittmair; Alexander Tichy; Barbara Nell
Journal:  Vet Ophthalmol       Date:  2019-02-17       Impact factor: 1.644

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.