Literature DB >> 15946874

DENSE with SENSE.

Anthony H Aletras1, W Patricia Ingkanisorn, Christine Mancini, Andrew E Arai.   

Abstract

Displacement encoding with stimulated echoes (DENSE) with a low encoding strength phase-cycled meta-DENSE readout and a two fold SENSE acceleration (R = 2) is described. This combination reduces total breath-hold times for increased patient comfort during cardiac regional myocardial contractility studies. Images from phantoms, normal volunteers, and a patient are provided to demonstrate the SENSE-DENSE combination of methods. The overall breath-hold time is halved while preserving strain map quality.

Entities:  

Mesh:

Year:  2005        PMID: 15946874     DOI: 10.1016/j.jmr.2005.05.010

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  9 in total

Review 1.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

Review 2.  Quantification of regional myocardial wall motion by cardiovascular magnetic resonance.

Authors:  Kai Jiang; Xin Yu
Journal:  Quant Imaging Med Surg       Date:  2014-10

Review 3.  Iron overload cardiomyopathy: better understanding of an increasing disorder.

Authors:  Pradeep Gujja; Douglas R Rosing; Dorothy J Tripodi; Yukitaka Shizukuda
Journal:  J Am Coll Cardiol       Date:  2010-09-21       Impact factor: 24.094

4.  Complementary prognostic values of stress myocardial perfusion and late gadolinium enhancement imaging by cardiac magnetic resonance in patients with known or suspected coronary artery disease.

Authors:  Kevin Steel; Ryan Broderick; Vijay Gandla; Eric Larose; Frederick Resnic; Michael Jerosch-Herold; Kenneth A Brown; Raymond Y Kwong
Journal:  Circulation       Date:  2009-09-21       Impact factor: 29.690

5.  Optimal configuration of respiratory navigator gating for the quantification of left ventricular strain using spiral cine displacement encoding with stimulated echoes (DENSE) MRI.

Authors:  Sean M Hamlet; Christopher M Haggerty; Jonathan D Suever; Gregory J Wehner; Kristin N Andres; David K Powell; Xiaodong Zhong; Brandon K Fornwalt
Journal:  J Magn Reson Imaging       Date:  2016-07-26       Impact factor: 4.813

6.  Systolic myocardial dysfunction in patients with type 2 diabetes mellitus: identification at MR imaging with cine displacement encoding with stimulated echoes.

Authors:  Laura Ernande; Hélène Thibault; Cyrille Bergerot; Phillippe Moulin; Han Wen; Geneviève Derumeaux; Pierre Croisille
Journal:  Radiology       Date:  2012-08-28       Impact factor: 11.105

7.  Numerical and in vivo validation of fast cine displacement-encoded with stimulated echoes (DENSE) MRI for quantification of regional cardiac function.

Authors:  Li Feng; Robert Donnino; James Babb; Leon Axel; Daniel Kim
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

Review 8.  MR and CT Imaging for the Evaluation of Pulmonary Hypertension.

Authors:  Benjamin H Freed; Jeremy D Collins; Christopher J François; Alex J Barker; Michael J Cuttica; Naomi C Chesler; Michael Markl; Sanjiv J Shah
Journal:  JACC Cardiovasc Imaging       Date:  2016-06

9.  Clinical experience of strain imaging using DENSE for detecting infarcted cardiac segments.

Authors:  Johan Kihlberg; Henrik Haraldsson; Andreas Sigfridsson; Tino Ebbers; Jan E Engvall
Journal:  J Cardiovasc Magn Reson       Date:  2015-06-24       Impact factor: 5.364

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.