Literature DB >> 15945014

Long-term persistence of fascia lata patch graft in glaucoma drainage device surgery.

E Gutiérrez-Díaz1, M Montero-Rodríguez, E Mencía-Gutiérrez, A Cabello, J Monescillo.   

Abstract

PURPOSE: Conjunctival erosion in glaucoma drainage device surgery can be prevented by the use of patch grafts to cover the extraocular portion of the tube. Several materials can be used, among them human preserved fascia lata.
METHODS: The authors present a case of a failed Ahmed glaucoma valve due to encapsulation of the bleb, in which the fascia lata patch placed to cover the tube was removed 32 months later, during the implantation of a second glaucoma drainage device.
RESULTS: Histopathologic examination of the fascia lata patch demonstrated its persistence, without degradation or cellular infiltration.
CONCLUSIONS: Human preserved fascia lata is a suitable material for tube covering in glaucoma drainage device surgery, with long-term survival.

Entities:  

Mesh:

Year:  2005        PMID: 15945014

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  7 in total

1.  Baerveldt® glaucoma implant surgery with the double scleral flap technique to prevent Hoffman elbow exposure.

Authors:  Naoki Tojo; Tomoko Ueda-Consolvo; Shuichiro Yanagisawa; Atsushi Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-07-22       Impact factor: 3.117

2.  Clinical outcomes of gamma-irradiated sterile cornea in aqueous drainage device surgery: a multicenter retrospective study.

Authors:  Q Pan; H D Jampel; P Ramulu; G F Schwartz; F Cotter; D Cute; Y J Daoud; P Murakami; W J Stark
Journal:  Eye (Lond)       Date:  2016-11-11       Impact factor: 3.775

3.  Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft).

Authors:  Feyzahan Ekici; Marlene R Moster; Victor Cvintal; Wanda D Hu; Michael Waisbourd
Journal:  Clin Ophthalmol       Date:  2015-05-04

4.  A novel surgical technique for prevention of Ahmed glaucoma valve tube exposure: long scleral flap augmented with Tenon advancement and duplication.

Authors:  O M Gedar Totuk; K Kabadayi; A Colakoglu; N Ekizoglu; U Aykan
Journal:  BMC Ophthalmol       Date:  2018-08-31       Impact factor: 2.209

5.  Electron Beam Irradiated Corneal Versus Gamma-Irradiated Scleral Patch Graft Erosion Rates in Glaucoma Drainage Device Surgery.

Authors:  Ross M Passo; Zachary B Hoskins; Khoa D Tran; Corrina Patzer; Beth Edmunds; John C Morrison; Mansi Parikh; Hana L Takusagawa; Shandiz Tehrani
Journal:  Ophthalmol Ther       Date:  2019-06-06

6.  Partial thickness cornea tissue from small incision lenticule extraction: A novel patch graft in glaucoma drainage implant surgery.

Authors:  Yuhong Wang; Xiaofeng Li; Weiyi Huang; Jinkun Liu; Yazhang Xu; Meizhu Chen; Qian Wang
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

7.  Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery.

Authors:  Meenakshi Chaku; Peter A Netland; Kyoko Ishida; Douglas J Rhee
Journal:  Clin Ophthalmol       Date:  2016-03-30