Literature DB >> 15936713

Statistical error in isothermal titration calorimetry: variance function estimation from generalized least squares.

Joel Tellinghuisen1.   

Abstract

The method of generalized least squares (GLS) is used to assess the variance function for isothermal titration calorimetry (ITC) data collected for the 1:1 complexation of Ba(2+) with 18-crown-6 ether. In the GLS method, the least squares (LS) residuals from the data fit are themselves fitted to a variance function, with iterative adjustment of the weighting function in the data analysis to produce consistency. The data are treated in a pooled fashion, providing 321 fitted residuals from 35 data sets in the final analysis. Heteroscedasticity (nonconstant variance) is clearly indicated. Data error terms proportional to q(i) and q(i)/v are well defined statistically, where q(i) is the heat from the ith injection of titrant and v is the injected volume. The statistical significance of the variance function parameters is confirmed through Monte Carlo calculations that mimic the actual data set. For the data in question, which fall mostly in the range of q(i)=100-2000 microcal, the contributions to the data variance from the terms in q(i)(2) typically exceed the background constant term for q(i)>300 microcal and v<10 microl. Conversely, this means that in reactions with q(i) much less than this, heteroscedasticity is not a significant problem. Accordingly, in such cases the standard unweighted fitting procedures provide reliable results for the key parameters, K and DeltaH(degrees) and their statistical errors. These results also support an important earlier finding: in most ITC work on 1:1 binding processes, the optimal number of injections is 7-10, which is a factor of 3 smaller than the current norm. For high-q reactions, where weighting is needed for optimal LS analysis, tips are given for using the weighting option in the commercial software commonly employed to process ITC data.

Entities:  

Mesh:

Year:  2005        PMID: 15936713     DOI: 10.1016/j.ab.2005.04.026

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  14 in total

Review 1.  Applications of isothermal titration calorimetry in RNA biochemistry and biophysics.

Authors:  Andrew L Feig
Journal:  Biopolymers       Date:  2007 Dec 5-15       Impact factor: 2.505

Review 2.  Global ITC fitting methods in studies of protein allostery.

Authors:  Lee Freiburger; Karine Auclair; Anthony Mittermaier
Journal:  Methods       Date:  2015-01-05       Impact factor: 3.608

Review 3.  Entropy-enthalpy compensation: role and ramifications in biomolecular ligand recognition and design.

Authors:  John D Chodera; David L Mobley
Journal:  Annu Rev Biophys       Date:  2013       Impact factor: 12.981

4.  Calix[4]pyrrole as a chloride anion receptor: solvent and countercation effects.

Authors:  Jonathan L Sessler; Dustin E Gross; Won-Seob Cho; Vincent M Lynch; Franz P Schmidtchen; Gareth W Bates; Mark E Light; Philip A Gale
Journal:  J Am Chem Soc       Date:  2006-09-20       Impact factor: 15.419

5.  Evaluation and Minimization of Uncertainty in ITC Binding Measurements: Heat Error, Concentration Error, Saturation, and Stoichiometry.

Authors:  Samuel A Kantonen; Niel M Henriksen; Michael K Gilson
Journal:  Biochim Biophys Acta Gen Subj       Date:  2016-09-15       Impact factor: 3.770

6.  Fitting two- and three-site binding models to isothermal titration calorimetric data.

Authors:  Chad A Brautigam
Journal:  Methods       Date:  2014-12-05       Impact factor: 3.608

Review 7.  Isothermal titration calorimetry of RNA.

Authors:  Nilshad N Salim; Andrew L Feig
Journal:  Methods       Date:  2008-10-07       Impact factor: 3.608

8.  Modeling complex equilibria in isothermal titration calorimetry experiments: thermodynamic parameters estimation for a three-binding-site model.

Authors:  Vu H Le; Robert Buscaglia; Jonathan B Chaires; Edwin A Lewis
Journal:  Anal Biochem       Date:  2012-12-19       Impact factor: 3.365

9.  Uncertainty in protein-ligand binding constants: asymmetric confidence intervals versus standard errors.

Authors:  Vaida Paketurytė; Vytautas Petrauskas; Asta Zubrienė; Olga Abian; Margarida Bastos; Wen-Yih Chen; Maria João Moreno; Georg Krainer; Vaida Linkuvienė; Arthur Sedivy; Adrian Velazquez-Campoy; Mark A Williams; Daumantas Matulis
Journal:  Eur Biophys J       Date:  2021-04-10       Impact factor: 1.733

10.  Preferential binding of K+ ions in the selectivity filter at equilibrium explains high selectivity of K+ channels.

Authors:  Shian Liu; Xuelin Bian; Steve W Lockless
Journal:  J Gen Physiol       Date:  2012-11-12       Impact factor: 4.086

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.