Literature DB >> 15936438

Visualization of anterior chamber angle dynamics using optical coherence tomography.

Christopher K S Leung1, Wai-Man Chan, Chun Yu Ko, Suk I Chui, Jackson Woo, Moon-Kong Tsang, Raymond Kwok Kay Tse.   

Abstract

PURPOSE: To describe the technology of optical coherence tomography (OCT) in imaging the anterior chamber angles and its impact on understanding the pathophysiology of angle-closure glaucoma (ACG).
DESIGN: Observational case series. PARTICIPANTS: Three subjects with, respectively, impending angle-closure attack, plateau iris syndrome, and phacomorphic glaucoma were recruited.
METHODS: The anterior chamber angle in each patient was imaged with a commercially available OCT unit. The angle configurations were assessed and compared before and after laser peripheral iridotomy (LPI) and argon laser peripheral iridoplasty (ALPI). MAIN OUTCOME MEASURES: Visualization of the changes in the anterior chamber angle configurations and normalization of the intraocular pressure (IOP).
RESULTS: A patient with impending angle-closure attack precipitated by a topical mydriatic agent was treated with LPI. Optical coherence tomography imaging of the anterior chamber angles was performed before and after the laser procedure. Conversion of anterior iris bowing and angle crowding to iris straightening and angle opening after LPI was demonstrated. Intraocular pressure became normalized with the change in angle configuration. The second patient presented with symptoms of intermittent angle-closure attacks and was initially diagnosed with primary ACG. Despite successful LPI, the angles remained occludable, and the IOP continued to be elevated. Optical coherence tomography was used to review the anterior chamber angle configuration and demonstrated a typical pattern compatible with the diagnosis of plateau iris syndrome. Subsequent ALPI converted the plateau configuration to open angle, with normalization of IOP and disappearance of symptoms. The third patient presented with an acute angle-closure attack and was diagnosed with phacomorphic glaucoma. Argon laser peripheral iridoplasty was performed successfully to open the angle, as evident by the OCT images, and the IOP was brought under control, together with relief of symptoms.
CONCLUSIONS: The commercially available OCT unit can be practically employed for anterior chamber angle imaging. The different patterns of angle configurations are correlated with the underlying pathophysiology in different forms of ACG.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15936438     DOI: 10.1016/j.ophtha.2005.01.022

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  23 in total

1.  Anterior optical coherence tomography: a non-contact technique for anterior chamber evaluation.

Authors:  Jens Dawczynski; Ekkehart Koenigsdoerffer; Regine Augsten; Juergen Strobel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-08-01       Impact factor: 3.117

2.  Reliable feature selection for automated angle closure glaucoma mechanism detection.

Authors:  S Issac Niwas; Weisi Lin; Xiaolong Bai; Chee Keong Kwoh; Chelvin C Sng; M Cecilia Aquino; P T K Chew
Journal:  J Med Syst       Date:  2015-02-08       Impact factor: 4.460

3.  Anterior chamber angle imaging with optical coherence tomography.

Authors:  C K-S Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-14       Impact factor: 3.775

4.  Determinants of anterior chamber angle narrowing after mydriasis in the patients with cataract.

Authors:  Shogo Arimura; Yoshihiro Takamura; Yuji Takihara; Takehiro Matsumura; Takeshi Tomomatsu; Masaru Inatani
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-10-14       Impact factor: 3.117

5.  Evaluation of the efficacy of laser peripheral iridoplasty in reversing the darkroom provocative test result in Chinese patients with primary angle closure status post laser iridotomy.

Authors:  Ping Huang; Ling-Ling Wu
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

6.  Semiautomatic procedure to assess changes in the eye accommodative system.

Authors:  Aikaterini I Moulakaki; Daniel Monsálvez-Romín; Alberto Domínguez-Vicent; José J Esteve-Taboada; Robert Montés-Micó
Journal:  Int Ophthalmol       Date:  2017-10-26       Impact factor: 2.031

7.  Changes in anterior chamber configuration after cataract surgery as measured by anterior segment optical coherence tomography.

Authors:  Martha Kim; Ki Ho Park; Tae-Woo Kim; Dong Myung Kim
Journal:  Korean J Ophthalmol       Date:  2011-03-11

8.  Optical coherence tomography in anterior segment imaging.

Authors:  Maya Kalev-Landoy; Alexander C Day; M Francesca Cordeiro; Clive Migdal
Journal:  Acta Ophthalmol Scand       Date:  2007-03-13

9.  Iris morphologic changes related to alpha(1)-adrenergic receptor antagonists implications for intraoperative floppy iris syndrome.

Authors:  Tiago Santos Prata; Pat-Michael Palmiero; Allison Angelilli; Zaher Sbeity; Carlos Gustavo V De Moraes; Jeffrey M Liebmann; Robert Ritch
Journal:  Ophthalmology       Date:  2009-05       Impact factor: 12.079

10.  Distributed scanning volumetric SDOCT for motion corrected corneal biometry.

Authors:  Ryan P McNabb; Francesco Larocca; Sina Farsiu; Anthony N Kuo; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2012-08-10       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.