Literature DB >> 15936099

Detection of viable Salmonella using microelectrode-based capacitance measurement coupled with immunomagnetic separation.

Liju Yang1, Yanbin Li.   

Abstract

In this study, we demonstrated the use of a general medium--brain heart infusion (BHI) broth that is not specifically formulated for impedance measurement, to achieve detectable impedance signals by using an interdigitated microelectrode (IME) with capacitance measurement at low frequencies. Anti-Salmonella antibody coated immunomagnetic beads were used to separate S. typhimurium from samples to provide the selectivity to this method. From analysis based on the equivalent circuit of the IME system, we found that the impedance change in BHI broth resulting from the growth of Salmonella was indeed the change in the double layer capacitance and could be monitored at 10 Hz using the IME. The results indicated that medium modification to improve impedance signal is not necessary with this IME system. However, effective immunological separation for the target organism is required for the selectivity when non-selective media are used. This finding provides a more flexible option of medium in impedance methods, which may provide opportunities to test those species of bacteria that have no suitable conductance growth medium. The detection time, t(d), was obtained from the impedance growth curve (impedance against bacterial growth time) at 10 Hz at the point where the impedance started to change. A linear relationship between the detection time and the logarithmic value of the initial cell number (N) was found in the Salmonella cell number ranging from 10(1) to 10(6) cfu/ml. The regression equation was t(d) = -1.22Log N + 8.90, with R2 = 0.95. The detection times for the initial cell number of 10(1) CFU/ml and 10(6) CFU/ml are 8 h and 1.5 h, respectively. This method is more sensitive than impedance methods using conventional electrodes.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15936099     DOI: 10.1016/j.mimet.2005.04.022

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  8 in total

1.  Towards the realization of label-free biosensors through impedance spectroscopy integrated with IDES technology.

Authors:  R Di Capua; M Barra; F Santoro; D Viggiano; P Ambrosino; M V Soldovieri; M Taglialatela; M Tagliatela; A Cassinese
Journal:  Eur Biophys J       Date:  2012-01-12       Impact factor: 1.733

2.  Development of a biochip using antibody-coated gold nanoparticles to detect specific bioparticles.

Authors:  Jung-Tang Huang; Shao-Yi Hou; Shiuh-Bin Fang; Hua-Wei Yu; Hung-Chan Lee; Chu-Zen Yang
Journal:  J Ind Microbiol Biotechnol       Date:  2008-08-26       Impact factor: 3.346

3.  Probing the membrane potential of living cells by dielectric spectroscopy.

Authors:  Corina Bot; C Prodan
Journal:  Eur Biophys J       Date:  2009-07-05       Impact factor: 1.733

Review 4.  Electrochemical biosensors for pathogen detection.

Authors:  Ellen Cesewski; Blake N Johnson
Journal:  Biosens Bioelectron       Date:  2020-04-12       Impact factor: 10.618

Review 5.  New trends in impedimetric biosensors for the detection of foodborne pathogenic bacteria.

Authors:  Yixian Wang; Zunzhong Ye; Yibin Ying
Journal:  Sensors (Basel)       Date:  2012-03-12       Impact factor: 3.576

6.  Optimization of electrically active magnetic nanoparticles as accurate and efficient microbial extraction tools.

Authors:  Barbara C Cloutier; Ashley K Cloutier; Evangelyn C Alocilja
Journal:  Biosensors (Basel)       Date:  2015-02-05

7.  Application of an Impedimetric Technique for the Detection of Lytic Infection of Salmonella spp. by Specific Phages.

Authors:  Lara R P Amorim; Joana G L Silva; Paul A Gibbs; Paula C Teixeira
Journal:  Int J Microbiol       Date:  2009-11-23

8.  Interdigitated and Wave-Shaped Electrode-Based Capacitance Sensor for Monitoring Antibiotic Effects.

Authors:  Jinsoo Park; Yonghyun Lee; Youjin Hwang; Sungbo Cho
Journal:  Sensors (Basel)       Date:  2020-09-14       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.