Literature DB >> 15933113

A conceptual optimisation strategy for radiography in a digital environment.

Magnus Båth1, Markus Håkansson, Jonny Hansson, Lars Gunnar Månsson.   

Abstract

Using a completely digital environment for the entire imaging process leads to new possibilities for optimisation of radiography since many restrictions of screen/film systems, such as the small dynamic range and the lack of possibilities for image processing, do not apply any longer. However, at the same time these new possibilities lead to a more complicated optimisation process, since more freedom is given to alter parameters. This paper focuses on describing an optimisation strategy that concentrates on taking advantage of the conceptual differences between digital systems and screen/film systems. The strategy can be summarised as: (a) always include the anatomical background during the optimisation, (b) perform all comparisons at a constant effective dose and (c) separate the image display stage from the image collection stage. A three-step process is proposed where the optimal setting of the technique parameters is determined at first, followed by an optimisation of the image processing. In the final step the optimal dose level-given the optimal settings of the image collection and image display stages-is determined.

Mesh:

Year:  2005        PMID: 15933113     DOI: 10.1093/rpd/nch567

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  A method to produce and validate a digitally reconstructed radiograph-based computer simulation for optimisation of chest radiographs acquired with a computed radiography imaging system.

Authors:  C S Moore; G P Liney; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2011-10       Impact factor: 3.039

2.  Large dose reduction by optimization of multifrequency processing software in digital radiography at follow-up examinations of the pediatric femur.

Authors:  Helle Precht; Oke Gerke; Karen Rosendahl; Anders Tingberg; Dag Waaler
Journal:  Pediatr Radiol       Date:  2013-12-24

3.  Can image enhancement allow radiation dose to be reduced whilst maintaining the perceived diagnostic image quality required for coronary angiography?

Authors:  Anuja Joshi; Amber J Gislason-Lee; Claire Keeble; Uduvil M Sivananthan; Andrew G Davies
Journal:  Br J Radiol       Date:  2017-01-26       Impact factor: 3.039

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.