Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1.

Hartmut Illers1, Egbert Buhr, Christoph Hoeschen.   

Abstract

A mobile measurement facility which complies with IEC 62220-1 has been set up to determine the detective quantum efficiency (DQE) of digital X-ray detector systems. Exemplary measurements were performed for two similar CR detector systems, a CsI-based indirect detector and an Se-based direct detector. The standardised radiation quality RQA 5 was applied for measurement and for three of these systems RQA 9 was also applied. A pronounced dependence of DQE on radiation quality was observed for the direct detector, where the DQEs for RQA 5 and RQA 9 differ by a factor of approximately 2. The uncertainty (95% confidence interval) associated with the measured DQE values is within 0.01 and 0.04 depending on, for example, the spatial frequency. Thus, it has been demonstrated that the DQE can be measured accurately and reliably with the accuracy required by the international standard IEC 62220-1. It is now possible to objectively measure and compare DQE values of digital X-ray detector systems.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15933079     DOI: 10.1093/rpd/nch507

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Effective DQE (eDQE) and speed of digital radiographic systems: an experimental methodology.

Authors:  Ehsan Samei; Nicole T Ranger; Alistair MacKenzie; Ian D Honey; James T Dobbins; Carl E Ravin
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

2.  Negative threshold voltage shift in an a-IGZO thin film transistor under X-ray irradiation.

Authors:  Dong-Gyu Kim; Jong-Un Kim; Jun-Sun Lee; Kwon-Shik Park; Youn-Gyoung Chang; Myeong-Ho Kim; Duck-Kyun Choi
Journal:  RSC Adv       Date:  2019-07-03       Impact factor: 4.036

3.  Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography.

Authors:  Tobias J Dietrich; Christian W A Pfirrmann; Alexander Schwab; Katja Pankalla; Florian M Buck
Journal:  Skeletal Radiol       Date:  2013-03-28       Impact factor: 2.199

4.  Detector or system? Extending the concept of detective quantum efficiency to characterize the performance of digital radiographic imaging systems.

Authors:  Ehsan Samei; Nicole T Ranger; Alistair MacKenzie; Ian D Honey; James T Dobbins; Carl E Ravin
Journal:  Radiology       Date:  2008-12       Impact factor: 11.105

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.