Literature DB >> 15927978

Changes in false lumen after transluminal stent-graft placement in aortic dissections: six years' experience.

Hitoshi Kusagawa1, Takatsugu Shimono, Masaki Ishida, Tomoaki Suzuki, Fuyuhiko Yasuda, Uhito Yuasa, Koji Onoda, Isao Yada, Tadanori Hirano, Kan Takeda, Noriyuki Kato.   

Abstract

BACKGROUND: Transluminal stent-graft placements (TSGPs) are a new, less invasive procedure now recognized as the choice for aortic disease repair. Treatment of aortic dissections with TSGPs has resulted in good early results, but the long-term results and changes in the false lumen have not been elucidated in detail. METHODS AND
RESULTS: TSGPs were performed in 49 patients with primary tears in their descending aortas, and the follow-up period ranged from 4 months to 6 years. The patients were divided into 32 acute-onset and 17 chronic dissections; of the acute-onset cases, there were 15 Stanford type A retrograde dissections. Periodic enhanced spiral CT was conducted after TSGP. The false lumen in the ascending aorta in 14 (93%) of the Stanford type A cases was obliterated completely within 3 months. The CT study was continued for >2 years for 17 acute-onset dissection and 11 chronic dissection patients. The average false lumen diameters of the proximal, middle, and distal descending aorta before treatment were 15.9, 16.2, and 15.6 mm in the acute-onset dissection group and 28.1, 25.2, and 21.0 mm in the chronic dissection group, respectively. The false lumen diameters 2 years after treatment were 3.0, 3.7, and 3.1 mm in the acute-onset dissection group and 10.6, 10.5, and 11.9 mm in the chronic dissection group, respectively. Two years after TSGPs, the false lumen of the thoracic aorta totally disappeared in 76% of the acute-onset dissection group and 36% of the chronic dissection group. No cases showed rupture after TSGP.
CONCLUSIONS: Complete obliteration of the false lumen is more likely in acute-onset cases than in chronic cases.

Entities:  

Mesh:

Year:  2005        PMID: 15927978     DOI: 10.1161/CIRCULATIONAHA.104.480780

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  16 in total

1.  Unusual complications of endovascular repair of the thoracic aorta: MDCT findings.

Authors:  T Valente; G Rossi; F Lassandro; G Rea; M Marino; G Dialetto; R Muto; M Scaglione
Journal:  Radiol Med       Date:  2012-01-07       Impact factor: 3.469

2.  Endovascular treatment of acute Type A aortic dissection-the Endo Bentall approach.

Authors:  Maximilian Kreibich; Bartosz Rylski; Stoyan Kondov; Julia Morlock; Johannes Scheumann; Fabian A Kari; Holger Schröfel; Matthias Siepe; Friedhelm Beyersdorf; Martin Czerny
Journal:  J Vis Surg       Date:  2018-04-04

Review 3.  Open surgical repair for chronic type B aortic dissection: a systematic review.

Authors:  David H Tian; Ramesh P De Silva; Tom Wang; Tristan D Yan
Journal:  Ann Cardiothorac Surg       Date:  2014-07

Review 4.  How should we manage type B aortic dissections?

Authors:  J Fleerakkers; M Schepens
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-08-29

Review 5.  Indication of endovascular treatment of type B aortic dissection--literature review.

Authors:  João Jackson Duarte; José Carlos Dorsa Vieira Pontes; Ricardo Adala Benfatti; Adriana Lugo Ferrachini; Walter Kegham Karakhanian; Alvaro Razuk Filho
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Jul-Sep

6.  Endovascular management for ruptured Stanford B acute aortic dissection.

Authors:  Atsushi Aoki; Takanori Suezawa; Kenji Sangawa; Mamoru Tago
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-02-10

7.  Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases.

Authors:  Geert Maleux; Johan Vaninbroukx; Sam Heye
Journal:  J Cardiothorac Surg       Date:  2011-04-08       Impact factor: 1.637

8.  Endovascular management of chronic post-dissection aneurysms.

Authors:  Kyriakos Oikonomou; Athanasios Katsargyris; Wolfgang Ritter; Domenico Spinelli; Yuki Seto; Eric L Verhoeven
Journal:  Ann Cardiothorac Surg       Date:  2014-05

9.  Predictors of false lumen thrombosis in type B aortic dissection treated with TEVAR.

Authors:  Jip L Tolenaar; John A Kern; Frederik H W Jonker; Kenneth J Cherry; Megan C Tracci; John F Angle; Saher Sabri; Santi Trimarchi; David Strider; Gorav Alaiwaidi; Gilbert R Upchurch
Journal:  Ann Cardiothorac Surg       Date:  2014-05

10.  Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment.

Authors:  Wan Naimah Wan Ab Naim; Zhonghua Sun; Yih Miin Liew; Bee Ting Chan; Shirley Jansen; Jing Lei; Poo Balan Ganesan; Shahrul Amry Hashim; Ganiga Srinivasaiah Sridhar; Einly Lim
Journal:  Quant Imaging Med Surg       Date:  2021-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.