Literature DB >> 15926182

Influence of stent surface topography on the outcomes of patients undergoing coronary stenting: a randomized double-blind controlled trial.

Alban Dibra1, Adnan Kastrati, Julinda Mehilli, Jürgen Pache, Randolf von Oepen, Josef Dirschinger, Albert Schömig.   

Abstract

The objective of this study was to examine the relationship between stent surface topography and outcome in patients undergoing implantation of stents with rough and smooth surfaces. Surface topography is considered an important determinant of the bare stent performance. Specifically designed rough surface may increase the drug-storing capacity of stents but its direct impact on the risk of thrombosis and restenosis is not known. A total of 200 patients with significant stenosis in native coronary vessels were randomly assigned in a double-blind way to receive either a rough or a smooth-surface stent. The primary endpoint of the study was late lumen loss. Secondary endpoints included angiographic restenosis and clinical outcomes. The study was designed to test the equivalence of rough-surface stents to smooth-surface stents with respect to late lumen loss based on a noninferiority margin of 0.20 mm. Follow-up angiography was performed in 77% of the patients. Late lumen loss was 1.0 +/- 0.7 mm in the rough-surface stent group and 1.2 +/- 0.7 mm in the smooth stent surface group with a mean difference of -0.20 mm (95% CI = -0.43 to 0.02) between the two stents (P < 0.001 from test for equivalence and P = 0.08 from test for superiority). Angiographic restenosis rates were 25% with rough-surface stents and 35% with smooth-surface stents (P = 0.19). These results show that a rough stent surface does not increase late lumen loss after stent implantation as compared with a conventional smooth stent surface.

Entities:  

Mesh:

Year:  2005        PMID: 15926182     DOI: 10.1002/ccd.20400

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  11 in total

1.  Low-dose sirolimus-eluting hydroxyapatite coating on stents does not increase platelet activation and adhesion ex vivo.

Authors:  Carlos L Alviar; Armando Tellez; Michael Wang; Pamela Potts; Doug Smith; Manus Tsui; Wladyslaw Budzynski; Albert E Raizner; Neal S Kleiman; Eli I Lev; Juan F Granada; Greg L Kaluza
Journal:  J Thromb Thrombolysis       Date:  2012-07       Impact factor: 2.300

2.  Coating process and early stage adhesion evaluation of poly(2-hydroxy-ethyl-methacrylate) hydrogel coating of 316L steel surface for stent applications.

Authors:  Laura Indolfi; Filippo Causa; Paolo Antonio Netti
Journal:  J Mater Sci Mater Med       Date:  2009-03-09       Impact factor: 3.896

Review 3.  Percutaneous coronary intervention: balloons, stents and scaffolds.

Authors:  Roisin Colleran; Adnan Kastrati
Journal:  Clin Res Cardiol       Date:  2018-07-23       Impact factor: 5.460

4.  Thromboresistant and endothelialization effects of dopamine-mediated heparin coating on a stent material surface.

Authors:  In-Ho Bae; In-Kyu Park; Dae Sung Park; Haeshin Lee; Myung Ho Jeong
Journal:  J Mater Sci Mater Med       Date:  2012-03-03       Impact factor: 3.896

5.  Rapid prototyped sutureless anastomosis device from self-curing silk bio-ink.

Authors:  Rod R Jose; Waseem K Raja; Ahmed M S Ibrahim; Pieter G L Koolen; Kuylhee Kim; Abdurrahman Abdurrob; Jonathan A Kluge; Samuel J Lin; Gillian Beamer; David L Kaplan
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-11-11       Impact factor: 3.368

Review 6.  Microfabrication and nanotechnology in stent design.

Authors:  Adam W Martinez; Elliot L Chaikof
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2011-01-31

7.  Hemodynamically driven stent strut design.

Authors:  Juan M Jiménez; Peter F Davies
Journal:  Ann Biomed Eng       Date:  2009-05-27       Impact factor: 3.934

8.  Surface projections of titanium substrates increase antithrombotic endothelial function in response to shear stress.

Authors:  Alexandra E Jantzen; Hardean E Achneck; George A Truskey
Journal:  J Biomed Mater Res A       Date:  2013-04-02       Impact factor: 4.396

9.  Human aortic endothelial cell response to 316L stainless steel material microstructure.

Authors:  Animesh Choubey; Denes Marton; Eugene A Sprague
Journal:  J Mater Sci Mater Med       Date:  2009-05-23       Impact factor: 3.896

10.  Continuously Grooved Stent Struts for Enhanced Endothelial Cell Seeding.

Authors:  Marja Ter Meer; Willeke F Daamen; Yvonne L Hoogeveen; Gijs J F van Son; Jeremy E Schaffer; J Adam van der Vliet; Leo J Schultze Kool; Lambertus P van den Heuvel
Journal:  Cardiovasc Intervent Radiol       Date:  2017-05-03       Impact factor: 2.740

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.