Literature DB >> 15914483

Feasibility of integrating high-spatial-resolution 3D breath-hold coronary MR angiography with myocardial perfusion and viability examinations.

Thomas K F Foo1, Vincent B Ho, Manojkumar Saranathan, Liu-quan Cheng, Hajime Sakuma, Dara L Kraitchman, Katherine C Wu, David A Bluemke.   

Abstract

The study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. All subjects provided informed consent. Three-dimensional breath-hold coronary magnetic resonance (MR) angiography with use of steady-state free precession was performed in 12 patients up to 20 minutes after 0.2 mmol gadolinium-based contrast material per kilogram of body weight was administered. Within 24 heartbeats, a spatial resolution of up to 1.0 x 1.2 x 2.0 mm was achieved. Sixty-five (82%) of the 79 visualized coronary artery segments had a grade of 3 or 4 on a four-point scale of depiction in which grade 4 indicated excellent depiction. Twenty-seven percent (n = 21) of the 79 segments were assigned a grade of 4; 56% (n = 44), a grade of 3; 16% (n = 13), a grade of 2; and 1% (n = 1), a grade of 1. Coronary MR angiography performed as part of a first-pass myocardial perfusion and viability assessment MR imaging examination is feasible and does not involve additional imaging time. Copyright RSNA, 2005.

Entities:  

Mesh:

Year:  2005        PMID: 15914483     DOI: 10.1148/radiol.2353040090

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

Review 1.  Anomalous origination of a coronary artery from the opposite sinus.

Authors:  Joanna C E Lim; Andy Beale; Steve Ramcharitar
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

2.  5D whole-heart sparse MRI.

Authors:  Li Feng; Simone Coppo; Davide Piccini; Jerome Yerly; Ruth P Lim; Pier Giorgio Masci; Matthias Stuber; Daniel K Sodickson; Ricardo Otazo
Journal:  Magn Reson Med       Date:  2017-05-11       Impact factor: 4.668

3.  Comprehensive adenosine stress perfusion MRI defines the etiology of chest pain in the emergency room: Comparison with nuclear stress test.

Authors:  Jens Vogel-Claussen; Jan Skrok; David Dombroski; Steven M Shea; Edward P Shapiro; Mark Bohlman; Christine H Lorenz; Joao A C Lima; David A Bluemke
Journal:  J Magn Reson Imaging       Date:  2009-10       Impact factor: 4.813

4.  Towards a five-minute comprehensive cardiac MR examination using highly accelerated parallel imaging with a 32-element coil array: feasibility and initial comparative evaluation.

Authors:  Jian Xu; Daniel Kim; Ricardo Otazo; Monvadi B Srichai; Ruth P Lim; Leon Axel; Kelly Anne Mcgorty; Thoralf Niendorf; Daniel K Sodickson
Journal:  J Magn Reson Imaging       Date:  2012-11-29       Impact factor: 4.813

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.