Literature DB >> 15911657

The use of cementless expansion acetabular component and an alumina-polyethylene bearing in total hip arthroplasty for osteonecrosis.

Y-G Kim1, S-Y Kim, S-J Kim, B-C Park, P-T Kim, J-C Ihn.   

Abstract

We performed 114 consecutive primary total hip arthroplasties with a cementless expansion acetabular component in 101 patients for advanced osteonecrosis of the femoral head. The mean age of the patients at surgery was 51 years (36 to 62) and the mean length of follow-up was 110 months (84 to 129). The mean pre-operative Harris hip score of 47 points improved to 93 points at final follow-up. The polyethylene liner was exchanged in two hips during this period and one broken acetabular component was revised. The mean linear wear rate of polyethylene was 0.07 mm/year and peri-acetabular osteolysis was seen in two hips (1.9%). Kaplan-Meier analysis indicated that the survival of the acetabular component without revision was 97.8% (95% confidence interval 0.956 to 1.000) at ten years. Our study has shown that the results of THA with a cementless expansion acetabular component and an alumina-polyethylene bearing surface are good.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15911657     DOI: 10.1302/0301-620X.87B6.15380

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

1.  Hip resurfacing in patients who have osteonecrosis and are 25 years or under.

Authors:  Siraj A Sayeed; Aaron J Johnson; D Alex Stroh; Thomas P Gross; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

2.  Outcomes of total hip arthroplasty in patients with osteonecrosis of the femoral head-a current review.

Authors:  Todd P Pierce; Randa K Elmallah; Julio J Jauregui; Daniel F Verna; Michael A Mont
Journal:  Curr Rev Musculoskelet Med       Date:  2015-09

3.  Sciatic nerve compression by an extrapelvic cyst secondary to wear debris after a cementless total hip arthroplasty: A case report and literature review.

Authors:  Murat Mert; Yusuf Oztürkmen; Ethem Ayhan Unkar; Sinan Erdoğan; Onat Uzümcügil
Journal:  Int J Surg Case Rep       Date:  2013-07-29

Review 4.  Osteonecrosis is not a predictor of poor outcomes in primary total hip arthroplasty: a systematic literature review.

Authors:  Henning R Johannson; Michael G Zywiel; David R Marker; Lynne C Jones; Mike S McGrath; Michael A Mont
Journal:  Int Orthop       Date:  2010-02-25       Impact factor: 3.075

5.  Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

Authors:  Yup Lee Jung; Shin-Yoon Kim
Journal:  Open Orthop J       Date:  2010-02-11

6.  A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up.

Authors:  Shijun Wang; ShuDong Zhang; YuChi Zhao
Journal:  J Orthop Surg Res       Date:  2013-07-08       Impact factor: 2.359

7.  A cementless, elastic press-fit socket with and without screws.

Authors:  Dean Pakvis; Joan Luites; Gijs van Hellemondt; Maarten Spruit
Journal:  Acta Orthop       Date:  2012-10       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.