Literature DB >> 15907701

Denaturation of lysozyme and myoglobin in laser spray.

Atsushi Takamizawa1, Susumu Fujimaki, Jan Sunner, Kenzo Hiraoka.   

Abstract

In laser spray, the tip of an electrospray capillary is irradiated with a continuous CO(2) laser beam. Here, we report results from a modified laser spray method that employs a relatively low laser irradiance level. With a laser power of approximately 2 W and a focal spot size ( approximately 0.3 mm), which covered the entire front surface of the electrospray capillary, the irradiance was approximately 3 x 10(3) W/cm(2). This resulted in a quiescent and smooth vaporization of aqueous solutions. This "evaporation-mode" laser spray method yielded the best results so far obtained in our laboratory with laser-irradiated electrospray, producing higher and more stable signals. The method was applied to the analysis of aqueous solutions of lysozyme and myoglobin. Mass spectra were obtained as a function of laser power from 0 W (electrospray) to approximately 2 W. The spray generated at the tip of the stainless steel capillary was observed with a CCD camera. With increase of laser power, the droplets in the spray became finer and the Taylor cone became progressively smaller. The strongest ion signals were recorded when the sample solution protruded only slightly from the tip of the capillary. A broadening of the lysozyme charge-state distribution, attributable to protein unfolding, was observed with a laser power of 2 W. No denaturation of myoglobin took place up to a laser power of 1.6 W. However, a sudden onset of denaturation was observed at 1.8 W as a broadening of the myoglobin charge distribution and the appearance of apo-myoglobin peaks. These findings demonstrate that laser spray is capable of dissociating the noncovalent complexes selectively without breaking covalent bonds.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15907701     DOI: 10.1016/j.jasms.2005.02.012

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  22 in total

1.  Detection of intact hemoglobin from aqueous solution with laser desorption mass spectrometry.

Authors:  A Wattenberg; F Sobott; B Brutschy
Journal:  Rapid Commun Mass Spectrom       Date:  2000       Impact factor: 2.419

2.  A comparative study of laser spray and electrospray

Authors: 
Journal:  Rapid Commun Mass Spectrom       Date:  2000       Impact factor: 2.419

3.  Origin of the conformation dependence of protein charge-state distributions in electrospray ionization mass spectrometry.

Authors:  Rita Grandori
Journal:  J Mass Spectrom       Date:  2003-01       Impact factor: 1.982

4.  Thermal dissociation of multimeric protein complexes by using nanoelectrospray mass spectrometry.

Authors:  Justin L P Benesch; Frank Sobott; Carol V Robinson
Journal:  Anal Chem       Date:  2003-05-15       Impact factor: 6.986

5.  Structure of myoglobin: A three-dimensional Fourier synthesis at 2 A. resolution.

Authors:  J C KENDREW; R E DICKERSON; B E STRANDBERG; R G HART; D R DAVIES; D C PHILLIPS; V C SHORE
Journal:  Nature       Date:  1960-02-13       Impact factor: 49.962

Review 6.  Studying noncovalent protein complexes by electrospray ionization mass spectrometry.

Authors:  J A Loo
Journal:  Mass Spectrom Rev       Date:  1997 Jan-Feb       Impact factor: 10.946

7.  Acid-induced denaturation of myoglobin studied by time-resolved electrospray ionization mass spectrometry.

Authors:  L Konermann; F I Rosell; A G Mauk; D J Douglas
Journal:  Biochemistry       Date:  1997-05-27       Impact factor: 3.162

8.  Structure of myoglobin refined at 2-0 A resolution. I. Crystallographic refinement of metmyoglobin from sperm whale.

Authors:  T Takano
Journal:  J Mol Biol       Date:  1977-03-05       Impact factor: 5.469

9.  Spectroscopic studies of myoglobin at low pH: heme structure and ligation.

Authors:  J T Sage; D Morikis; P M Champion
Journal:  Biochemistry       Date:  1991-02-05       Impact factor: 3.162

10.  Electrochemical processes in a wire-in-a-capillary bulk-loaded, nano-electrospray emitter.

Authors:  G J Van Berkel; K G Asano; P D Schnier
Journal:  J Am Soc Mass Spectrom       Date:  2001-07       Impact factor: 3.262

View more
  5 in total

1.  Microfluidic Chip Coupled with Thermal Desorption Atmospheric Pressure Ionization Mass Spectrometry.

Authors:  Chia-Hsien Chang; Tsung-Yi Chen; Yu-Chie Chen
Journal:  Mass Spectrom (Tokyo)       Date:  2014-05-01

2.  Evaluation of binding affinity of protein-mutant DNA complexes in solution by laser spray mass spectrometry.

Authors:  Xiangguo Shi; Yoshifumi Nishimura; Satoko Akashi; Atsushi Takamizawa; Kenzo Hiraoka
Journal:  J Am Soc Mass Spectrom       Date:  2006-02-20       Impact factor: 3.109

3.  High pressure super-heated electrospray ionization mass spectrometry for sub-critical aqueous solution.

Authors:  Lee Chuin Chen; Md Matiur Rahman; Kenzo Hiraoka
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-10       Impact factor: 3.109

4.  Melting proteins confined in nanodroplets with 10.6 μm light provides clues about early steps of denaturation.

Authors:  Tarick J El-Baba; Daniel R Fuller; Daniel W Woodall; Shannon A Raab; Christopher R Conant; Jonathan M Dilger; Yoni Toker; Evan R Williams; David H Russell; David E Clemmer
Journal:  Chem Commun (Camb)       Date:  2018-03-27       Impact factor: 6.222

5.  On the distributions of ion/neutral molecule clusters in electrospray and laser spray -- a cluster division model for the electrospray process.

Authors:  Jan Sunner; Iwona B Beech; Kenzo Hiraoka
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-19       Impact factor: 3.109

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.