CEDIA sirolimus assay compared with HPLC-MS/MS and HPLC-UV in transplant recipient specimens.

Ian S Westley1, Raymond G Morris, Paul J Taylor, Paul Salm, Maree J James.   

Abstract

The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA SRL assay has the potential to improve this situation. The present communication has compared the CEDIA SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 microg/L and 20 microg/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 microg/L and 20 microg/L, respectively. The lower limit of quantification was found to be 3.0 microg/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA method showed a Deming regression line of CEDIA=1.20xHPLC-MS/MS-0.07 (r=0.934, SEE=.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15905801     DOI: 10.1097/01.ftd.0000164394.47520.12

Source DB:  PubMed          Journal:  Ther Drug Monit        ISSN: 0163-4356            Impact factor:   3.681


  2 in total

Review 1.  Therapeutic drug monitoring in pediatric renal transplantation.

Authors:  Lutz T Weber
Journal:  Pediatr Nephrol       Date:  2014-04-25       Impact factor: 3.714

2.  Determination of blood sirolimus concentrations in liver and kidney transplant recipients using the Innofluor fluorescence polarization immunoassay: comparison with the microparticle enzyme immunoassay and high-performance liquid chromatography-ultraviolet method.

Authors:  Lorena Bouzas; Jesús Hermida; J Carlos Tutor
Journal:  Ups J Med Sci       Date:  2009       Impact factor: 2.384

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.