Literature DB >> 1590229

Simultaneous transesophageal two-dimensional echocardiography and atrial pacing for detecting coronary artery disease.

O Kamp1, C C De Cock, A J Küpper, J P Roos, C A Visser.   

Abstract

This study describes a new technique for assessing wall motion abnormalities, combining transesophageal echocardiography (TEE) and transesophageal atrial pacing in 71 patients. Stable capture was reached in 70 patients (99%). In 3 patients (4%) pacing was discontinued prematurely because of discomfort. TEE during pacing was performed in 52 patients with and in 18 patients without coronary artery disease (CAD). In 43 of 52 patients with CAD, regional wall motion abnormalities occurred (sensitivity 83%). No wall motion abnormalities occurred in 17 of 18 patients without CAD (specificity 94%, positive predictive value 98%). Wall motion abnormalities related to another vascular region were observed in 17 of 22 patients with previous myocardial infarction (sensitivity 77%, specificity 100%, positive predictive value 100%). Simultaneous 12-lead electrocardiography during atrial pacing was performed in 57 patients and yielded positive results in 21 of 40 patients with (sensitivity 52%) and in 3 of 17 patients without (specificity 82%, positive predictive value 88%) CAD. Exercise stress testing was performed in 66 patients. Twenty-four of 48 patients with CAD had a positive exercise electrocardiogram (sensitivity 50%); a false-positive exercise electrocardiogram was observed in 3 of 18 patients (specificity 83%, positive predictive value 89%). It is concluded that TEE during transesophageal atrial pacing is a feasible and promising alternative technique for the assessment of CAD, with a higher sensitivity than simultaneous 12-lead and exercise electrocardiography.

Entities:  

Mesh:

Year:  1992        PMID: 1590229     DOI: 10.1016/0002-9149(92)90892-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

1.  Detection of coronary stenoses by stress echocardiography using a previously implanted pacemaker for ventricular pacing: preliminary report of a new method.

Authors:  D Benchimol; M Mazanof; B Dubroca; H Benchimol; V Bernard; T Couffinhal; J F Dartigues; R Roudaut; X Pillois; J Bonnet
Journal:  Clin Cardiol       Date:  2000-11       Impact factor: 2.882

2.  A meta-analytic comparison of echocardiographic stressors.

Authors:  Yoshinori Noguchi; Shizuko Nagata-Kobayashi; James E Stahl; John B Wong
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.