Literature DB >> 15899446

Assessment of central corneal thickness using optical coherence tomography.

Gary R Fishman1, Mauricio E Pons, John A Seedor, Jeffrey M Liebmann, Robert Ritch.   

Abstract

PURPOSE: To demonstrate the capability of model OCT3 optical coherence tomographer to evaluate central corneal thickness (CCT) in normal human corneas in vivo and compare the results with the those of standard ultrasound (US) pachymetry and Orbscan.
SETTING: New York Eye & Ear Infirmary Resident Clinic, New York, New York, USA.
METHODS: The CCT in 22 eyes of 11 subjects was determined with the OCT3 (Carl Zeiss Meditec), Orbscan (Bausch & Lomb, Inc.), and US pachymetry (DGH Technology, Inc.). Three central corneal scans of each eye were obtained using the OCT3. First, OCT3 data were processed using the standard OCT software program (OCT3(std)). Second, OCT3 raw data were exported and measurements were repeated using Scion Image for Windows program (OCT3(sci)). The OCT3 and Orbscan results were compared with the mean of 5 US pachymetry measurements in each eye.
RESULTS: The OCT3(std), OCT3(sci), and Orbscan CCT measurements showed high correlations with US pachymetry (r=0.981, r=0.984, and r=0.942, respectively; P<.0001). Bland-Altman analysis showed a high level of agreement between US pachymetry and OCT3 techniques but not Orbscan. High repeatability for OCT3(std) (r(2)=0.05) and OCT3(sci) (r(2)=0.01) was also seen.
CONCLUSION: Results show the OCT3 is an accurate, noninvasive, and reproducible technique for evaluation of CCT.

Entities:  

Mesh:

Year:  2005        PMID: 15899446     DOI: 10.1016/j.jcrs.2004.09.021

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry.

Authors:  Hanna Y Kim; Donald L Budenz; Pak S Lee; William J Feuer; Keith Barton
Journal:  Am J Ophthalmol       Date:  2007-12-11       Impact factor: 5.258

2.  Corneal pachymetry mapping with high-speed optical coherence tomography.

Authors:  Yan Li; Raj Shekhar; David Huang
Journal:  Ophthalmology       Date:  2006-05       Impact factor: 12.079

3.  Relationships between central and peripheral corneal thickness in different degrees of myopia.

Authors:  Sara Ortiz; Laura Mena; Ana Rio-San Cristobal; Raul Martin
Journal:  J Optom       Date:  2013-05-16

4.  Measurement of Central Corneal Thickness Using Ultrasound Pachymetry and Orbscan II in Normal Eyes.

Authors:  Mohammad Mehdi Sadoughi; Bahram Einollahi; Neda Einollahi; Javad Rezaei; Danial Roshandel; Sepehr Feizi
Journal:  J Ophthalmic Vis Res       Date:  2015 Jan-Mar

5.  Distribution of corneal thickness and its determinants in 6-12-year-old children in an Iranian general population.

Authors:  Hassan Hashemi; Mohammad Saatchi; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Abbasali Yekta; Akbar Fotouhi
Journal:  J Curr Ophthalmol       Date:  2017-12-23

6.  Changes in Central Corneal Thickness With Air-Puff-Induced Corneal Deformation Using a Method to Correct Scheimpflug and Refractive Distortion.

Authors:  Monica D Okon; Yanhui Ma; Jun Liu; Cynthia J Roberts
Journal:  J Refract Surg       Date:  2021-06-01       Impact factor: 3.255

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.