Literature DB >> 15899279

Disinfectant efficacy of chlorite and chlorine dioxide in drinking water biofilms.

G A Gagnon1, J L Rand, K C O'leary, A C Rygel, C Chauret, R C Andrews.   

Abstract

The drinking water industry is closely examining options to maintain disinfection in distribution systems. In particular this research compared the relative efficiency of the chlorite ion (ClO2-) to chlorine dioxide (ClO2) for biofilm control. Chlorite levels were selected for monitoring since they are typically observed in the distribution system as a by-product whenever chlorine dioxide is applied for primary or secondary disinfection. Previous research has reported the chlorite ion to be effective in mitigating nitrification in distribution systems. Annular reactors (ARs) containing polycarbonate and cast iron coupons were used to simulate water quality conditions in a distribution system. Following a 4 week acclimation period, individual ARs operated in parallel were dosed with high (0.25mg/l) and low (0.1mg/l) chlorite concentrations and with high (0.5 mg/l) and low (0.25mg/l) chlorine dioxide concentrations, as measured in the effluent of the AR. Another set of ARs that contained cast iron and polycarbonate coupons served as controls and did not receive any disinfection. The data presented herein show that the presence of chlorite at low concentration levels was not effective at reducing heterotrophic bacteria. Log reductions of attached heterotrophic bacteria for low and high chlorite ranged between 0.20 and 0.34. Chlorine dioxide had greater log reductions for attached heterotrophic bacteria ranging from 0.52 to 1.36 at the higher dose. The greatest log reduction in suspended heterotrophic bacteria was for high dose of ClO2 on either cast iron or polycarbonate coupons (1.77 and 1.55). These data indicate that it would be necessary to maintain a chlorine dioxide residual concentration in distribution systems for control of microbiological regrowth.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15899279     DOI: 10.1016/j.watres.2005.02.004

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  15 in total

1.  Bacteriological quality of drinking water in Nyala, South Darfur, Sudan.

Authors:  Amira Ahmed Abdelrahman; Yassir Mohammed Eltahir
Journal:  Environ Monit Assess       Date:  2010-05-18       Impact factor: 2.513

2.  Topical adjuvants incompletely remove adherent Staphylococcus aureus from implant materials.

Authors:  Emily P Ernest; Anthony S Machi; Brock A Karolcik; Paul R LaSala; Matthew J Dietz
Journal:  J Orthop Res       Date:  2017-11-30       Impact factor: 3.494

3.  Diversity and functions of bacterial community in drinking water biofilms revealed by high-throughput sequencing.

Authors:  Yuanqing Chao; Yanping Mao; Zhiping Wang; Tong Zhang
Journal:  Sci Rep       Date:  2015-06-12       Impact factor: 4.379

4.  Comparing methods of determining Legionella spp. in complex water matrices.

Authors:  Álvaro Díaz-Flores; Juan Carlos Montero; Francisco Javier Castro; Eva María Alejandres; Carmen Bayón; Inmaculada Solís; Roberto Fernández-Lafuente; Guillermo Rodríguez
Journal:  BMC Microbiol       Date:  2015-04-29       Impact factor: 3.605

5.  Susceptibility of Legionella strains to the chlorinated biocide, monochloramine.

Authors:  Delphine Jakubek; Carole Guillaume; Marie Binet; Gérard Leblon; Michael DuBow; Matthieu Le Brun
Journal:  Microbes Environ       Date:  2013-09-03       Impact factor: 2.912

Review 6.  Pseudomonas aeruginosa in premise plumbing of large buildings.

Authors:  Emilie Bédard; Michèle Prévost; Eric Déziel
Journal:  Microbiologyopen       Date:  2016-06-28       Impact factor: 3.139

Review 7.  Biotechnological Applications of Microbial (Per)chlorate Reduction.

Authors:  Ouwei Wang; John D Coates
Journal:  Microorganisms       Date:  2017-11-24

8.  Microbicidal effects of weakly acidified chlorous acid water against feline calicivirus and Clostridium difficile spores under protein-rich conditions.

Authors:  Hisataka Goda; Hitoshi Yamaoka; Haruyuki Nakayama-Imaohji; Hiroyuki Kawata; Isanori Horiuchi; Yatsuka Fujita; Tamiko Nagao; Ayano Tada; Atsushi Terada; Tomomi Kuwahara
Journal:  PLoS One       Date:  2017-05-04       Impact factor: 3.240

Review 9.  Copper Corrosion and Biocorrosion Events in Premise Plumbing.

Authors:  Ignacio T Vargas; Diego A Fischer; Marco A Alsina; Juan P Pavissich; Pablo A Pastén; Gonzalo E Pizarro
Journal:  Materials (Basel)       Date:  2017-09-05       Impact factor: 3.623

10.  Effect of supernatant water level on As removal in biological rapid sand filters.

Authors:  J C J Gude; K Joris; K Huysman; L C Rietveld; D van Halem
Journal:  Water Res X       Date:  2018-11-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.