Literature DB >> 15897284

Dosimetry of digital panoramic imaging. Part I: Patient exposure.

F Gijbels1, R Jacobs, R Bogaerts, D Debaveye, S Verlinden, G Sanderink.   

Abstract

OBJECTIVES: To measure patient radiation dose during panoramic exposure with various panoramic units for digital panoramic imaging.
METHODS: An anthropomorphic phantom was filled with thermoluminescent dosemeters (TLD 100) and exposed with five different digital panoramic units during ten consecutive exposures. Four machines were equipped with a direct digital CCD (charge coupled device) system, whereas one of the units used storage phosphor plates (indirect digital technique). The exposure settings recommended by the different manufacturers for the particular image and patient size were used: tube potential settings ranged between 64 kV and 74 kV, exposure times between 8.2 s and 19.0 s, at fuse current values between 4 mA and 7 mA. The effective radiation dose was calculated with inclusion of the salivary glands.
RESULTS: Effective radiation doses ranged between 4.7 microSv and 14.9 microSv for one exposure. Salivary glands absorbed the most radiation for all panoramic units. When indirect and direct digital panoramic systems were compared, the effective dose of the indirect digital unit (8.1 microSv) could be found within the range of the effective doses for the direct digital units (4.7-14.9 microSv).
CONCLUSIONS: A rather wide range of patient radiation doses can be found for digital panoramic units. There is a tendency for lower effective doses for digital compared with analogue panoramic units, reported in previous studies.

Entities:  

Mesh:

Year:  2005        PMID: 15897284     DOI: 10.1259/dmfr/28107460

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  19 in total

Review 1.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

Review 2.  State-of-the-art on cone beam CT imaging for preoperative planning of implant placement.

Authors:  Maria Eugenia Guerrero; Reinhilde Jacobs; Miet Loubele; Filip Schutyser; Paul Suetens; Daniel van Steenberghe
Journal:  Clin Oral Investig       Date:  2006-02-16       Impact factor: 3.573

3.  Shielding effect of thyroid collar for digital panoramic radiography.

Authors:  G-S Han; J-G Cheng; G Li; X-C Ma
Journal:  Dentomaxillofac Radiol       Date:  2013-09-04       Impact factor: 2.419

4.  Influence of lead apron shielding on absorbed doses from panoramic radiography.

Authors:  D Rottke; L Grossekettler; K Sawada; P Poxleitner; D Schulze
Journal:  Dentomaxillofac Radiol       Date:  2013-10-30       Impact factor: 2.419

5.  Assessment of variations of the mandibular canal through cone beam computed tomography.

Authors:  Christiano de Oliveira-Santos; Paulo Henrique Couto Souza; Soraya de Azambuja Berti-Couto; Lien Stinkens; Kristin Moyaert; Izabel Regina Fischer Rubira-Bullen; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2011-03-30       Impact factor: 3.573

6.  Patient radiation dose and protection from cone-beam computed tomography.

Authors:  Gang Li
Journal:  Imaging Sci Dent       Date:  2013-06-14

7.  The value of thyroid shielding in intraoral radiography.

Authors:  Reinier C Hoogeveen; Bart Hazenoot; Gerard C H Sanderink; W Erwin R Berkhout
Journal:  Dentomaxillofac Radiol       Date:  2016-03-23       Impact factor: 2.419

8.  Skin entrance dose with and without lead apron in digital panoramic radiography for selected sensitive body regions.

Authors:  Ralf Kurt Willy Schulze; Catrin Cremers; Heiko Karle; Hugo de Las Heras Gala
Journal:  Clin Oral Investig       Date:  2016-06-21       Impact factor: 3.573

9.  Does dose optimisation in digital panoramic radiography affect diagnostic performance?

Authors:  Luciano Augusto Cano Martins; Danieli M Brasil; Laís A Forner; Cassiana Viccari; Francisco Haiter-Neto; Deborah Q Freitas; Matheus L Oliveira
Journal:  Clin Oral Investig       Date:  2020-08-26       Impact factor: 3.573

10.  The reduction of dose in paediatric panoramic radiography: the impact of collimator height and programme selection.

Authors:  A T Davis; H Safi; S M Maddison
Journal:  Dentomaxillofac Radiol       Date:  2014-10-29       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.