Nicole Lamond1, Drew Dawson, Gregory D Roach. 1. The Centre for Sleep Research, The University of South Australia, Adelaide, SA, Australia. nicole.lamond@unisa.edu.au
Abstract
INTRODUCTION: In recent years, there has been an increasing need for a reliable and practical tool for assessing fatigue-related impairment in the field. This study investigated the sensitivity of one potential tool, a 5-min version of the psychomotor vigilance task (PVT) specifically designed for use on personal digital assistants (PDA), to 28 h of sustained wakefulness. METHODS: There were 15 participants who slept in the laboratory overnight then remained awake from 08:00 (Day 1) to 12:00 (Day 2). During every second hour, they completed a 10-min PVT, a sustained attention task that is sensitive to the effects of sleep loss and fatigue, and a 5-min PDA-PVT. RESULTS: While performance on both tasks significantly varied as a function of hours of wakefulness, responses on the PDA-PVT were typically slower than on the PVT. When performance scores were standardized, the negative impact of increasing hours of wakefulness on performance on the 5-min PDA-PVT and 10-min PVT did not significantly differ. DISCUSSION: The findings suggest that the 5-min PDA-PVT may provide a reasonable substitute for the 10-min PVT, particularly in circumstances where a shorter test is required and/or the standard PVT is not as practical.
INTRODUCTION: In recent years, there has been an increasing need for a reliable and practical tool for assessing fatigue-related impairment in the field. This study investigated the sensitivity of one potential tool, a 5-min version of the psychomotor vigilance task (PVT) specifically designed for use on personal digital assistants (PDA), to 28 h of sustained wakefulness. METHODS: There were 15 participants who slept in the laboratory overnight then remained awake from 08:00 (Day 1) to 12:00 (Day 2). During every second hour, they completed a 10-min PVT, a sustained attention task that is sensitive to the effects of sleep loss and fatigue, and a 5-min PDA-PVT. RESULTS: While performance on both tasks significantly varied as a function of hours of wakefulness, responses on the PDA-PVT were typically slower than on the PVT. When performance scores were standardized, the negative impact of increasing hours of wakefulness on performance on the 5-min PDA-PVT and 10-min PVT did not significantly differ. DISCUSSION: The findings suggest that the 5-min PDA-PVT may provide a reasonable substitute for the 10-min PVT, particularly in circumstances where a shorter test is required and/or the standard PVT is not as practical.
Authors: Marjorie Vennelle; Sandra White; Renata L Riha; Tom W Mackay; Heather M Engleman; Neil J Douglas Journal: Sleep Date: 2010-02 Impact factor: 5.849
Authors: Mitchell R Smith; Chris Thompson; Samuele M Marcora; Sabrina Skorski; Tim Meyer; Aaron J Coutts Journal: Sports Med Date: 2018-07 Impact factor: 11.136
Authors: Anand R Rose; Peter G Catcheside; R Doug McEvoy; Denzil Paul; Dilip Kapur; Emily Peak; Andrew Vakulin; Nicholas A Antic Journal: J Clin Sleep Med Date: 2014-08-15 Impact factor: 4.062
Authors: Catherine S Cole; Mark Mennemeier; James E Bost; Laura Smith-Olinde; Diane Howieson Journal: Biol Res Nurs Date: 2011-10-09 Impact factor: 2.522
Authors: Laura K Barger; Jason P Sullivan; Andrea S Vincent; Edna R Fiedler; Laurence M McKenna; Erin E Flynn-Evans; Kirby Gilliland; Walter E Sipes; Peter H Smith; George C Brainard; Steven W Lockley Journal: Sleep Date: 2012-10-01 Impact factor: 5.849