BACKGROUND AND PURPOSE: Squamous cell carcinoma (SCC) and lymphoma are common malignant tumors of the head and neck. The purpose of this study was to determine whether the apparent diffusion coefficient (ADC) in line scan diffusion-weighted imaging (LSDWI) is useful for distinguishing between SCC and lymphoma of the head and neck. METHODS: LSDWI was prospectively performed in 39 patients with SCC and in 14 patients with lymphoma. Images were obtained with a diffusion-weighted factor (b factor) of 5 and 1000 s/mm(2), and ADC maps were generated. ADC values were measured for the two types of tumor. RESULTS: Mean ADC values were 0.96 +/- 0.11 x 10(-3) mm(2)/s for SCC and 0.65 +/- 0.09 x 10(-3) mm(2)/s for lymphoma; the difference was significant (P < .001). All but one of the patients with lymphoma had ADC values lower than the lowest ADC (0.76 x 10(-3) mm(2)/s) in patients with SCC. When an ADC of 0.76 x 10(-3) mm(2)/s was used to distinguish between SCC and lymphoma, accuracy was 98% (52 of 53 lesions). CONCLUSION: ADC values appear to be useful for distinguishing between SCC and lymphoma in the head and neck.
BACKGROUND AND PURPOSE:Squamous cell carcinoma (SCC) and lymphoma are common malignant tumors of the head and neck. The purpose of this study was to determine whether the apparent diffusion coefficient (ADC) in line scan diffusion-weighted imaging (LSDWI) is useful for distinguishing between SCC and lymphoma of the head and neck. METHODS: LSDWI was prospectively performed in 39 patients with SCC and in 14 patients with lymphoma. Images were obtained with a diffusion-weighted factor (b factor) of 5 and 1000 s/mm(2), and ADC maps were generated. ADC values were measured for the two types of tumor. RESULTS: Mean ADC values were 0.96 +/- 0.11 x 10(-3) mm(2)/s for SCC and 0.65 +/- 0.09 x 10(-3) mm(2)/s for lymphoma; the difference was significant (P < .001). All but one of the patients with lymphoma had ADC values lower than the lowest ADC (0.76 x 10(-3) mm(2)/s) in patients with SCC. When an ADC of 0.76 x 10(-3) mm(2)/s was used to distinguish between SCC and lymphoma, accuracy was 98% (52 of 53 lesions). CONCLUSION: ADC values appear to be useful for distinguishing between SCC and lymphoma in the head and neck.
Authors: T Sugahara; Y Korogi; M Kochi; I Ikushima; Y Shigematu; T Hirai; T Okuda; L Liang; Y Ge; Y Komohara; Y Ushio; M Takahashi Journal: J Magn Reson Imaging Date: 1999-01 Impact factor: 4.813
Authors: R G González; P W Schaefer; F S Buonanno; L H Schwamm; R F Budzik; G Rordorf; B Wang; A G Sorensen; W J Koroshetz Journal: Radiology Date: 1999-01 Impact factor: 11.105
Authors: S E Maier; H Gudbjartsson; S Patz; L Hsu; K O Lovblad; R R Edelman; S Warach; F A Jolesz Journal: AJR Am J Roentgenol Date: 1998-07 Impact factor: 3.959
Authors: K O Lövblad; H J Laubach; A E Baird; F Curtin; G Schlaug; R R Edelman; S Warach Journal: AJNR Am J Neuroradiol Date: 1998 Jun-Jul Impact factor: 3.825
Authors: K S S Bhatia; A D King; D K W Yeung; F Mo; A C Vlantis; K-H Yu; J K T Wong; A T Ahuja Journal: Br J Radiol Date: 2010-07-20 Impact factor: 3.039
Authors: Ann D King; Frankie K F Mo; Kwok-Hung Yu; David K W Yeung; Hua Zhou; Kunwar S Bhatia; Gary M K Tse; Alexander C Vlantis; Jeffrey K T Wong; Anil T Ahuja Journal: Eur Radiol Date: 2010-03-23 Impact factor: 5.315
Authors: A Srinivasan; C J Galbán; T D Johnson; T L Chenevert; B D Ross; S K Mukherji Journal: AJNR Am J Neuroradiol Date: 2009-12-10 Impact factor: 3.825
Authors: Sungheon Kim; Laurie Loevner; Harry Quon; Eric Sherman; Gregory Weinstein; Alex Kilger; Harish Poptani Journal: Clin Cancer Res Date: 2009-02-01 Impact factor: 12.531