PURPOSE: To evaluate the concordance of the enhancement patterns of a new ultrasound contrast agent (SonoVue) with those obtained with dual-phase contrast-enhanced spiral CT (CE-CT) in the characterization of focal liver lesions (FLLs). MATERIALS AND METHODS: Sixty-two patients with focal liver lesions discovered at ultrasound and also studied with CECT underwent contrast-enhanced ultrasound using continuous low acoustic power imaging after receiving a 2.4 ml bolus of the new US contrast agent SonoVue, consisting of a dispersion of sulphur hexafluoride microbubbles. The examinations were made using ATL HDI-5000, Acuson SEQUOIA and Aloka 5500 Prosound ultrasound systems with 5.2 MHz curved-array probes. The concordance between US and CE-CT images was evaluated on site by two radiologists blinded to CT RESULTS: The FLLs were assessed in the arterial (20 s after CM injection), portal (after 45-60 s) and late (after 120 s) phases for: 1) presence/absence of enhancement 2) distribution of enhancement (homogenous or target distribution, centripetal or centrifugal flow, and other), 3) qualitative enhancement pattern (hyperechoic, hypoechoic, or isoechoic) versus normal liver parenchyma. RESULTS: The concordance between SonoVue-enhanced US and CE-CT was 85%. Moreover during portal venous phase with CEUS it was possible to differentiate between malignancy or benignity of 91% of lesions. CONCLUSIONS: The preliminary data obtained in this study suggest that continuous low acoustic power imaging and contrast-enhanced US show similar results to CT in contrast distribution and contrast enhancement patterns.
PURPOSE: To evaluate the concordance of the enhancement patterns of a new ultrasound contrast agent (SonoVue) with those obtained with dual-phase contrast-enhanced spiral CT (CE-CT) in the characterization of focal liver lesions (FLLs). MATERIALS AND METHODS: Sixty-two patients with focal liver lesions discovered at ultrasound and also studied with CECT underwent contrast-enhanced ultrasound using continuous low acoustic power imaging after receiving a 2.4 ml bolus of the new US contrast agent SonoVue, consisting of a dispersion of sulphur hexafluoride microbubbles. The examinations were made using ATL HDI-5000, Acuson SEQUOIA and Aloka 5500 Prosound ultrasound systems with 5.2 MHz curved-array probes. The concordance between US and CE-CT images was evaluated on site by two radiologists blinded to CT RESULTS: The FLLs were assessed in the arterial (20 s after CM injection), portal (after 45-60 s) and late (after 120 s) phases for: 1) presence/absence of enhancement 2) distribution of enhancement (homogenous or target distribution, centripetal or centrifugal flow, and other), 3) qualitative enhancement pattern (hyperechoic, hypoechoic, or isoechoic) versus normal liver parenchyma. RESULTS: The concordance between SonoVue-enhanced US and CE-CT was 85%. Moreover during portal venous phase with CEUS it was possible to differentiate between malignancy or benignity of 91% of lesions. CONCLUSIONS: The preliminary data obtained in this study suggest that continuous low acoustic power imaging and contrast-enhanced US show similar results to CT in contrast distribution and contrast enhancement patterns.
Authors: M D'Onofrio; F Vecchiato; V Cantisani; E Barbi; M Passamonti; P Ricci; R Malagò; N Faccioli; G Zamboni; R Pozzi Mucelli Journal: Radiol Med Date: 2008-02-25 Impact factor: 3.469
Authors: F Vecchiato; M D'Onofrio; R Malagò; E Martone; A Gallotti; N Faccioli; V Cantisani; C Marigliano; A Ruzzenente; R Pozzi Mucelli Journal: Radiol Med Date: 2009-06-23 Impact factor: 3.469
Authors: R Vilana; L Bianchi; M Varela; C Nicolau; M Sánchez; C Ayuso; M García; M Sala; J M Llovet; J Bruix; C Bru Journal: Eur Radiol Date: 2006-05-18 Impact factor: 7.034
Authors: Marcos Roberto Gomes de Queiroz; Miguel José Francisco Neto; Rodrigo Gobbo Garcia; Antonio Rahal Junior; Paolo Salvalaggio; Marcelo Buarque de Gusmão Funari Journal: Einstein (Sao Paulo) Date: 2013-12