Large particles are responsible for elevated bacterial marker levels in school air upon occupation.

Alvin Fox1, William Harley, Charles Feigley, Deborah Salzberg, Charlotte Toole, Aleksandra Sebastian, Lennart Larsson.   

Abstract

Muramic acid (Mur) is found in bacterial peptidoglycan (PG) whereas 3-hydroxy fatty acids (3-OH FAs) are found in Gram-negative bacterial lipopolysaccharide (LPS). Thus Mur and 3-OH FAs serve as markers to assess bacterial levels in indoor air. An initial survey, in a school, demonstrated that the levels of dust, PG and LPS (pmol m(-3)) were each much higher in occupied rooms than in the same rooms when unoccupied. In each instance, the Mur content of dust was increased and the hydroxy fatty acid distribution changed similarly suggesting an alteration in the bacterial population. Here, findings are compared with results from two additional schools. Follow-up aerosol monitoring by particle size was also performed for the first time for all 3 schools. The particle size distribution was shown to be quite different in occupied versus unoccupied schoolrooms. Within individual classrooms, concentrations of airborne particles [greater-than-or-equal]0.8 [micro sign]m in diameter, and CO(2) were correlated. This suggests that the increased levels of larger particles are responsible for elevation of bacterial markers during occupation. Release of culturable and non-culturable bacteria or bacterial aggregates from children (e.g. from flaking skin) might explain this phenomenon.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15877165     DOI: 10.1039/b418038k

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  8 in total

1.  Indoor and outdoor sources of size-resolved mass concentration of particulate matter in a school gym-implications for exposure of exercising children.

Authors:  Martin Braniš; Jiří Safránek; Adéla Hytychová
Journal:  Environ Sci Pollut Res Int       Date:  2010-10-24       Impact factor: 4.223

2.  αβ T cells and a mixed Th1/Th17 response are important in organic dust-induced airway disease.

Authors:  Jill A Poole; Angela M Gleason; Christopher Bauer; William W West; Neil Alexis; Stephen J Reynolds; Debra J Romberger; Tammy Kielian
Journal:  Ann Allergy Asthma Immunol       Date:  2012-07-24       Impact factor: 6.347

3.  An optimized method to detect influenza virus and human rhinovirus from exhaled breath and the airborne environment.

Authors:  Patricia Fabian; James Joseph McDevitt; Wai-Ming Lee; Eugene Andres Houseman; Donald Kirby Milton
Journal:  J Environ Monit       Date:  2008-12-01

4.  Size-resolved emission rates of airborne bacteria and fungi in an occupied classroom.

Authors:  J Qian; D Hospodsky; N Yamamoto; W W Nazaroff; J Peccia
Journal:  Indoor Air       Date:  2012-02-13       Impact factor: 5.770

5.  Human occupancy as a source of indoor airborne bacteria.

Authors:  Denina Hospodsky; Jing Qian; William W Nazaroff; Naomichi Yamamoto; Kyle Bibby; Hamid Rismani-Yazdi; Jordan Peccia
Journal:  PLoS One       Date:  2012-04-18       Impact factor: 3.240

6.  A longitudinal study of sick building syndrome (SBS) among pupils in relation to SO2, NO2, O3 and PM10 in schools in China.

Authors:  Xin Zhang; Fan Li; Li Zhang; Zhuohui Zhao; Dan Norback
Journal:  PLoS One       Date:  2014-11-14       Impact factor: 3.240

7.  Rhinitis, Ocular, Throat and Dermal Symptoms, Headache and Tiredness among Students in Schools from Johor Bahru, Malaysia: Associations with Fungal DNA and Mycotoxins in Classroom Dust.

Authors:  Dan Norbäck; Jamal Hisham Hashim; Gui-Hong Cai; Zailina Hashim; Faridah Ali; Erica Bloom; Lennart Larsson
Journal:  PLoS One       Date:  2016-02-01       Impact factor: 3.240

8.  Indoor bioaerosol dynamics.

Authors:  William W Nazaroff
Journal:  Indoor Air       Date:  2014-12-27       Impact factor: 5.770

  8 in total