Literature DB >> 15868529

Intraoperative glucose control in diabetic and nondiabetic patients during cardiac surgery.

Charles E Smith1, Nicholas R Styn, Satish Kalhan, Alfred C Pinchak, Inderjit S Gill, Richard P Kramer, Tejbir Sidhu.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate intraoperative glucose control.
DESIGN: Prospective unblinded study.
SETTING: Tertiary care center. PARTICIPANTS: Diabetic (n = 17) and nondiabetic (n = 23) patients undergoing elective cardiac surgery.
INTERVENTIONS: Diabetics received a modified insulin regimen consisting of a fixed rate infusion of regular insulin, 10 U/m2/h, and a variable infusion of D10W, adjusted to maintain glucose between 101 to 140 mg/dL.
MEASUREMENTS AND MAIN RESULTS: Baseline glucose was higher in diabetics versus nondiabetics (mean +/- standard error of the mean: 203 +/- 27 v 117 +/- 3 mg/dL, p < 0.005). After baseline, insulin levels were increased in diabetics to 410 to 568 microU/mL. Corresponding insulin levels in nondiabetics were 12 to 40 microU/mL. Compared with baseline, glucose was decreased by 10% +/- 29% in diabetics during hypothermic cardiopulmonary bypass and increased by 21% +/- 30% in nondiabetics (p < 0.005). After discontinuation of bypass, glucose was lower in diabetics (137 +/- 12 mg/dL) versus nondiabetics (162 +/- 8 mg/dL, p < 0.005). Nine diabetics had adequate intraoperative glycemic control during hypothermic bypass (glucose 123 +/- 8 mg/dL, insulin 550 +/- 68 microU/mL, glucose infusion rate 1.87 +/- 0.29 mg/kg/min), 6 approached adequate control near the end of surgery (glucose 147 +/- 8 mg/dL, insulin 483 +/- 86 microU/mL, glucose infusion rate 0.35 +/- 0.05 mg/kg/min), and 2 never achieved control. Diabetics with elevated initial glucose >300 mg/dL did not achieve adequate glycemic control. Four diabetics (3 with renal failure) required injection of 50% dextrose after bypass for hypoglycemia.
CONCLUSION: Adequate glycemic control can be achieved in most diabetics during cardiac surgery using a modified insulin clamp technique provided initial glucose is <300 mg/dL.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15868529     DOI: 10.1053/j.jvca.2005.01.032

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  6 in total

1.  Glycemic variability and mortality in critically ill patients: the impact of diabetes.

Authors:  James Stephen Krinsley
Journal:  J Diabetes Sci Technol       Date:  2009-11-01

2.  Use of a continuous glucose sensor in an extracorporeal life support circuit.

Authors:  Garry M Steil; Jamin Alexander; Alexandra Papas; Langer Monica; Biren P Modi; Hannah Piper; Tom Jaksic; Rebecca Gottlieb; Michael S D Agus
Journal:  J Diabetes Sci Technol       Date:  2011-01-01

3.  Inadequate blood glucose control is associated with in-hospital mortality and morbidity in diabetic and nondiabetic patients undergoing cardiac surgery.

Authors:  R Ascione; C A Rogers; C Rajakaruna; G D Angelini
Journal:  Circulation       Date:  2008-07-08       Impact factor: 29.690

4.  Intraoperative blood glucose levels in nondiabetic patients undergoing elective major surgery under general anaesthesia receiving different crystalloid solutions for maintenance fluid.

Authors:  Souvik Maitra; Jyotirmay Kirtania; Samaendra Pal; Sulagna Bhattacharjee; Amitava Layek; Shreyasi Ray
Journal:  Anesth Essays Res       Date:  2013 May-Aug

5.  Glucose metabolism in cardiovascular surgery.

Authors:  C Lazzeri; S Bevilacqua; F Ciappi; C Pratesi; G F Gensini; S Romagnoli
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2010

6.  Is elevated blood glucose a marker of occult tissue hypoperfusion in off-pump coronary artery bypass grafting?

Authors:  Soumi Das; Kakali Ghosh; Avijit Hazra; Chaitali Sen; Anupam Goswami
Journal:  Ann Card Anaesth       Date:  2018 Oct-Dec
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.