Literature DB >> 15866009

Comparison of contamination rates of catheter-drawn and peripheral blood cultures.

E S McBryde1, M Tilse, J McCormack.   

Abstract

The aim of this study was to assess the sensitivity and specificity of catheter-drawn and peripheral blood cultures. Paired blood culture samples collected over a 44-month period from a 280 bed Brisbane metropolitan hospital were analysed, using standard clinical and microbiological criteria, to determine whether blood culture isolates represented true bacteraemias or contamination. Catheter-collected cultures had a specificity of 85% compared with 97% for peripheral cultures. In only two instances (0.2%) was the diagnosis of clinically significant bacteraemia made on the basis of catheter culture alone. This study concluded that catheter-collected samples are not a good test for true bacteraemia, and that peripheral cultures are more reliable when the results of the paired cultures are discordant.

Entities:  

Mesh:

Year:  2005        PMID: 15866009     DOI: 10.1016/j.jhin.2004.10.020

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  8 in total

Review 1.  Updated review of blood culture contamination.

Authors:  Keri K Hall; Jason A Lyman
Journal:  Clin Microbiol Rev       Date:  2006-10       Impact factor: 26.132

2.  Blood cultures at central line insertion in the intensive care unit: comparison with peripheral venipuncture.

Authors:  Sheldon Stohl; Shmuel Benenson; Sigal Sviri; Alexander Avidan; Colin Block; Charles L Sprung; Phillip D Levin
Journal:  J Clin Microbiol       Date:  2011-04-27       Impact factor: 5.948

Review 3.  Effectiveness of practices to reduce blood culture contamination: a Laboratory Medicine Best Practices systematic review and meta-analysis.

Authors:  Susan R Snyder; Alessandra M Favoretto; Rich Ann Baetz; James H Derzon; Bereneice M Madison; Diana Mass; Colleen S Shaw; Christopher D Layfield; Robert H Christenson; Edward B Liebow
Journal:  Clin Biochem       Date:  2012-06-16       Impact factor: 3.281

4.  Blood drawn through valved catheter hub connectors carries a significant risk of contamination.

Authors:  R J Sherertz; T B Karchmer; E Palavecino; W Bischoff
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-05-01       Impact factor: 3.267

5.  Utility of peripheral blood cultures in bacteremic pediatric cancer patients with a central line.

Authors:  Katrin Scheinemann; Marie-Chantal Ethier; L Lee Dupuis; Susan E Richardson; John Doyle; Upton Allen; Lillian Sung
Journal:  Support Care Cancer       Date:  2009-08-29       Impact factor: 3.603

6.  Comparison of the detection of periodontal pathogens in bacteraemia after tooth brushing by culture and molecular techniques.

Authors:  M-J Marín; E Figuero; I González; A O'Connor; P Diz; M Álvarez; D Herrera; M Sanz
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-05-01

7.  Nonobstructive Acute Renal Failure with a Large Solitary Fibroid.

Authors:  Rayan Elkattah; Zineb Mashak; Blakele Bakker; Shanti Mohling; Ali Yilmaz; Stephen DePasquale; Todd Boren
Journal:  Case Rep Obstet Gynecol       Date:  2016-06-07

8.  A change of culture: reducing blood culture contamination rates in an Emergency Department.

Authors:  James Bentley; Shobhan Thakore; L Muir; Alastair Baird; Jennifer Lee
Journal:  BMJ Qual Improv Rep       Date:  2016-06-06
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.