Literature DB >> 15863091

Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement: case report and review of the literature.

Frank L Acosta1, Timothy L Thompson, Stacey Campbell, Philip R Weinstein, Christopher P Ames.   

Abstract

BACKGROUND CONTEXT: Three-dimensional (3D) fluoroscopy-based image guidance system using an isocentric C-arm (Iso-C) fluoroscope was shown to be as effective as computed tomography-based systems in guiding the accurate percutaneous placement of lumbar pedicle screws in cadavers. To date, however, no description is available of the intraoperative use of 3D fluoroscopy to guide lumbar pedicle screw placement in an actual spinal fusion procedure.
PURPOSE: We report a case in which isocentric 3D fluoroscopic images, along with image-guidance software, were used to guide the placement of percutaneous pedicle screws for fusion in a patient with degenerative spondylolisthesis. STUDY DESIGN/
SETTING: Operating room of a large academic medical center during the placement of percutaneous pedicle screws in a patient with degenerative spondylolisthesis.
METHODS: A percutaneous dynamic reference array was attached to the L3 spinous process. A satisfactory image set was obtained and automatically registered. The L4 and L5 pedicles were localized, and pedicle holes were then cannulated, drilled and tapped. A screw was then inserted using the Sextant system for percutaneous pedicle screws. In this manner, bilateral pedicle screws were inserted into the L4-L5 pedicles. All steps of pedicle cannulation were performed under Iso-C 3D image guidance.
RESULTS: A postoperative computed tomography scan showed accurate placement of all pedicle screws. The patient experienced an improvement in leg pain with no new neurologic deficits.
CONCLUSIONS: The present case is the first case to demonstrate the intraoperative use of a 3D fluoroscopy-based image-guidance system for accurate navigation during lumbar pedicle screw placement.

Entities:  

Mesh:

Year:  2005        PMID: 15863091     DOI: 10.1016/j.spinee.2004.09.012

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  15 in total

1.  O-arm(®)-based spinal navigation and intraoperative 3D-imaging: first experiences.

Authors:  O Gonschorek; S Hauck; U Spiegl; T Weiß; R Pätzold; V Bühren
Journal:  Eur J Trauma Emerg Surg       Date:  2011-03-31       Impact factor: 3.693

2.  [Cost-benefit analysis of intraoperative 3D imaging].

Authors:  T Hüfner; T Stübig; T Gösling; D Kendoff; J Geerling; C Krettek
Journal:  Unfallchirurg       Date:  2007-01       Impact factor: 1.000

3.  Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance.

Authors:  Eric W Nottmeier; Andrew B Foy
Journal:  Eur Spine J       Date:  2007-11-22       Impact factor: 3.134

Review 4.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

5.  Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation.

Authors:  Erin J Smith; Hisham A Al-Sanawi; Braden Gammon; Paul J St John; David R Pichora; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-06-25       Impact factor: 2.924

Review 6.  Percutaneous screw placement in the lumbar spine with a modified guidance technique based on 3D CT navigation system.

Authors:  Ioannis D Siasios; John Pollina; Asham Khan; Vassilios George Dimopoulos
Journal:  J Spine Surg       Date:  2017-12

7.  Minimally invasive percutaneous transpedicular screw fixation: increased accuracy and reduced radiation exposure by means of a novel electromagnetic navigation system.

Authors:  Ron von Jako; Michael A Finn; Kenneth S Yonemura; Ali Araghi; Larry T Khoo; John A Carrino; Mick Perez-Cruet
Journal:  Acta Neurochir (Wien)       Date:  2010-12-14       Impact factor: 2.216

8.  Minimally invasive pedicle screw placement in a case of L4 fracture: case report with review of literature.

Authors:  Abhishek Agrawal; Junichi Mizuno; Yoko Kato; Tatsushi Inoue; Hirotoshi Sano
Journal:  Asian J Neurosurg       Date:  2010-07

9.  Percutaneous pedicle screw placement in the thoracic spine: A cadaveric study.

Authors:  Carolyn A Hardin; Shahid M Nimjee; Isaac O Karikari; Abhishek Agrawal; Richard G Fessler; Robert E Isaacs
Journal:  Asian J Neurosurg       Date:  2013-07

10.  A New Electromagnetic Navigation System for Pedicle Screws Placement: A Human Cadaver Study at the Lumbar Spine.

Authors:  Patrick Hahn; Semih Oezdemir; Martin Komp; Athanasios Giannakopoulos; Roderich Heikenfeld; Richard Kasch; Harry Merk; Georgios Godolias; Sebastian Ruetten
Journal:  PLoS One       Date:  2015-07-29       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.