Literature DB >> 15863077

Hydroxyapatite-coating of pedicle screws improves resistance against pull-out force in the osteoporotic canine lumbar spine model: a pilot study.

Toru Hasegawa1, Akihiko Inufusa, Yoshiyuki Imai, Yoshihiro Mikawa, Tae-Hong Lim, Howard S An.   

Abstract

BACKGROUND CONTEXT: In patients with spinal osteoporosis, the early achievement and maintenance of a biological bond between the pedicle screw and bone is important to avoid screw loosening complications. There are few reports of in vivo investigations involving biomechanical and histological evaluations in the osteoporotic spine.
PURPOSE: To evaluate the effect of hydroxyapatite (HA)-coating on the pedicle screw in the osteoporotic lumbar spine and to investigate the relationship between resistance against the screw pull-out force and bone mineral density (BMD) of the vertebral body. STUDY DESIGN/
SETTING: Mechanical and pathological investigations in the lumbar spine.
METHODS: Two 24-month-old female beagle dogs were fed a calcium-free dog chow for 6 months after ovariectomy (OVX). BMD (in g/cm2) was measured by dual energy X-ray absorptiometry at pre-OVX and 6 months after OVX. Pedicle screws were placed from L1 to L6 at 6 months after OVX. Twenty-four pure titanium cortical screws (Synthes, #401-114) were used as pedicle screws (Ti-PS). Of these, 12 screws had HA-coating (HA-PS). The HA-PS screws were inserted into the right pedicles and the Ti-PS were inserted into the left pedicles. Ten days after this procedure, the lumbar spines were removed en bloc for screw pull-out testing and histological evaluation.
RESULTS: The mean BMD value of the lumbar vertebrae 6 months after the OVX was 0.549+/-0.087 g/cm2, which was significantly less than the pre-OVX mean BMD of 0.603+/-0.092 g/cm2 (p < 0.001). The mean resistance against the pull-out force for the HA-PS was significantly greater at 165.6+/-26.5N than in the Ti-PS (103.1+/-30.2N, p < .001). The histological sections in the HA-PS clearly revealed new bone bonding with the apatite coating but only fibrous tissue bonding in the Ti-PS.
CONCLUSIONS: The results of this study showed that the resistance to the pull-out force of HA-PS is 1.6 times that of Ti-PS. Furthermore, HA-PS has superior biological bonding to the surrounding bone, as early as 10 days after surgery in this osteoporotic spine model. Thus, in patients with osteoporosis, coating of the pedicle screw with HA may provide better stability and bonding between the pedicle screw and bone in the early postoperative period.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15863077     DOI: 10.1016/j.spinee.2004.11.010

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  29 in total

1.  An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model.

Authors:  Young Jae Moon; Jong-Kil Kim; Hong-Geun Oh; Ji-Hun Kang; Gun-Joo Park; Kwang-Bok Lee
Journal:  J Vis Exp       Date:  2017-05-31       Impact factor: 1.355

2.  A pedicle screw system and a lamina hook system provide similar primary and long-term stability: a biomechanical in vitro study with quasi-static and dynamic loading conditions.

Authors:  Hans-Joachim Wilke; Dominik Kaiser; David Volkheimer; Carsten Hackenbroch; Klaus Püschel; Michael Rauschmann
Journal:  Eur Spine J       Date:  2016-07-12       Impact factor: 3.134

3.  Can cavity-based pedicle screw augmentation decrease screw loosening? A biomechanical in vitro study.

Authors:  Hans-Joachim Riesner; Thomas R Blattert; Renate Krezdorn; Simone Schädler; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2020-12-23       Impact factor: 3.134

4.  Augmentation of implant fixation in osteoporotic bone.

Authors:  Clifford B Jones
Journal:  Curr Osteoporos Rep       Date:  2012-12       Impact factor: 5.096

5.  Anatomical research on strength of screw track fixation in novel cortical bone trajectory for osteoporosis lumbar spine.

Authors:  Paerhati Rexiti; Gulixian Aierken; Shuiquan Wang; Tuerhongjiang Abudurexiti; Nueraihemaiti Abuduwali; Qiang Deng; Hailong Guo; Weibin Sheng
Journal:  Am J Transl Res       Date:  2019-11-15       Impact factor: 4.060

6.  Treatment of unusual proximal humeral fractures using unilateral external fixator: a case series.

Authors:  Gökçer Uzer; Fatih Yıldız; Mehmet Elmadağ; Kerem Bilsel; Anil Pulatkan
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-12-19

7.  Surgical treatment of osteoporotic thoraco-lumbar compressive fractures: the use of pedicle screw with augmentation PMMA.

Authors:  Massimo Girardo; P Cinnella; G Gargiulo; P Viglierchio; A Rava; S Aleotti
Journal:  Eur Spine J       Date:  2017-03-21       Impact factor: 3.134

8.  Calcium phosphate coating formed in infusion fluid mixture to enhance fixation strength of titanium screws.

Authors:  Hirotaka Mutsuzaki; Atsuo Ito; Masataka Sakane; Yu Sogo; Ayako Oyane; Yuko Ebihara; Noboru Ichinose; Naoyuki Ochiai
Journal:  J Mater Sci Mater Med       Date:  2007-05-05       Impact factor: 3.896

9.  Inter-observer reliability of detecting Dynesys pedicle screw using plain X-rays: a study on 50 post-operative patients.

Authors:  Fras Dakhil-Jerew; H Jadeja; A Cohen; J A N Shepperd
Journal:  Eur Spine J       Date:  2009-06-16       Impact factor: 3.134

Review 10.  [Surgical management of adult scoliosis. The challenge of osteoporosis and adjacent level degeneration].

Authors:  M Quante; A Richter; B Thomsen; M Köszegvary; H Halm
Journal:  Orthopade       Date:  2009-02       Impact factor: 1.087

View more