Literature DB >> 15858789

Two-year follow-up intravascular ultrasound analysis after bare metal stent implantation in 120 lesions.

Myeong-Ki Hong1, Cheol Whan Lee, Young-Hak Kim, Bong-Ki Lee, Min-Kyu Kim, Tae-Hyun Yang, Jong-Min Song, Ki-Hoon Han, Duk-Hyun Kang, Jae-Kwan Song, Jae-Joong Kim, Seong-Wook Park, Seung-Jung Park.   

Abstract

The objective of this study was to examine long-term changes after bare metal stent implantation in a relatively large number of patients. There are few reports of intravascular ultrasound (IVUS) studies performed on stented and nonstented (reference) segments beyond 6 months after bare metal stenting. Using IVUS, we evaluated serial changes in stented and reference segments between 6 and 24 months after stent implantation in 110 patients with 120 lesions. Serial IVUS images were acquired at five equidistant intrastent sites and at two different reference segment sites. Measurements were made of the external elastic membrane (EEM), stent, lumen, and intimal hyperplasia (IH = stent - lumen) area. For the whole patient group, between 6 and 24 months, the mean IH area in stented segments decreased from 2.6 +/- 1.0 to 2.3 36+/- 0.9 mm2 (P < 0.001), and the mean lumen area increased from 6.2 +/- 2.0 to 6.5 +/- 1.9 mm2 (P < 0.001). The mean IH area decreased in 91 lesions (76%) and increased in 29 lesions (24%) between 6 and 24 months. There were no significant changes in EEM or lumen area in the reference segments. Late angiographic restenosis (diameter stenosis > or = 50%) occurred in three lesions between 6 and 24 months. A late target lesion revascularization was performed for one lesion. In the period of time between 6 and 24 months after stenting, IH regression occurred in most (76%) stent lesions, resulting in late lumen increase. However, IH progression was observed in 24% of in-stent lesions. No significant changes of EEM or lumen area occurred in the reference segments. Copyright 2005 Wiley-Liss, Inc

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15858789     DOI: 10.1002/ccd.20358

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

Review 1.  Induction of vascular atrophy as a novel approach to treating restenosis. A review.

Authors:  Seung-Kee Min; Richard D Kenagy; Alexander W Clowes
Journal:  J Vasc Surg       Date:  2007-10-22       Impact factor: 4.268

2.  Serial changes of neointimal tissue after everolimus-eluting stent implantation in porcine coronary artery: an optical coherence tomography analysis.

Authors:  Hoyoun Won; Jung-Sun Kim; Dong-Ho Shin; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Biomed Res Int       Date:  2014-09-18       Impact factor: 3.411

  2 in total