Absolute CD4 T-cell counting in resource-poor settings: direct volumetric measurements versus bead-based clinical flow cytometry instruments.

Tandakha Ndiaye Dieye1, Chris Vereecken, Abdoul Aziz Diallo, Pascale Ondoa, Papa Alassane Diaw, Makhtar Camara, Farba Karam, Souleymane Mboup, Luc Kestens.   

Abstract

Flow cytometry is an accurate but expensive method to determine absolute CD4 cell counts. We compared different methods to measure absolute CD4 counts in blood samples from HIV-infected and uninfected subjects using a research/clinical flow cytometer (FACScan); a dedicated clinical instrument (FACSCount); and a volumetric, mobile, open-system flow cytometer equipped with 3 fluorescence and 2 light scatter detectors (Cyflow SL blue). The FACScan and Cyflow were used as single-platform instruments, but they differ in running cost, which is a central factor for resource-poor settings. Direct volumetric and bead-based CD4 measurements on the Cyflow were compared with 2 bead-based single-platform CD4 measurements on the FACSCount and on FACScan (TruCount) in "Le Dantec" Hospital, Dakar, Senegal, using whole blood samples from 102 HIV+ and 28 HIV- subjects. The agreement between the various measurement methods was evaluated by Bland-Altman analysis. Volumetric CD4 measurements on the Cyflow using a no-lyse-no-wash (NLNW) procedure and a lyse-no-wash (LNW) procedure correlated well with each other (R2 = 0.98) and with CD4 measurements on the FACSCount (R2 = 0.97) and FACScan (R2 = 0.97), respectively. Red blood cell lysis had no negative effect on the accuracy of absolute CD4 counting on the Cyflow. An excellent correlation was observed between bead-based CD4 measurements on the Cyflow and CD4 measurements on the FACSCount (R2 = 0.99) and FACScan (R2 = 0.99). Rigid internal and external quality control monitoring and adequate training of technicians were considered essential to generate accurate volumetric CD4 measurements on the Cyflow.

Entities:  

Mesh:

Year:  2005        PMID: 15851911     DOI: 10.1097/01.qai.0000160515.20581.ad

Source DB:  PubMed          Journal:  J Acquir Immune Defic Syndr        ISSN: 1525-4135            Impact factor:   3.731


  20 in total

1.  Evaluation of a new single-parameter volumetric flow cytometer (CyFlow(green)) for enumeration of absolute CD4+ T lymphocytes in human immunodeficiency virus type 1-infected Thai patients.

Authors:  Kovit Pattanapanyasat; Surada Lerdwana; Egarit Noulsri; Thanyanan Chaowanachan; Punneeporn Wasinrapee; Natthaga Sakulploy; Vallerut Pobkeeree; Orapin Suksripanich; Sombat Thanprasertsuk; Thomas J Spira; Jordan W Tappero; William C Levine
Journal:  Clin Diagn Lab Immunol       Date:  2005-12

2.  Laboratory support of global health research.

Authors:  Barbara Van Der Pol
Journal:  J Gen Intern Med       Date:  2013-09       Impact factor: 5.128

Review 3.  The intersection of flow cytometry with microfluidics and microfabrication.

Authors:  Menake E Piyasena; Steven W Graves
Journal:  Lab Chip       Date:  2014-03-21       Impact factor: 6.799

4.  Validation of a single-platform, volumetric, CD45-assisted PanLeucogating Auto40 flow cytometer to determine the absolute number and percentages of CD4 T cells in resource-constrained settings using Cameroonian patients' samples.

Authors:  François-Xavier Mbopi-Kéou; Stefano Mion; Bertrand Sagnia; Laurent Bélec
Journal:  Clin Vaccine Immunol       Date:  2012-02-15

5.  A microfluidic device for practical label-free CD4(+) T cell counting of HIV-infected subjects.

Authors:  Xuanhong Cheng; Daniel Irimia; Meredith Dixon; Kazuhiko Sekine; Utkan Demirci; Lee Zamir; Ronald G Tompkins; William Rodriguez; Mehmet Toner
Journal:  Lab Chip       Date:  2006-11-24       Impact factor: 6.799

6.  Normal Range of CD4 Cell Counts and Temporal Changes in Two HIVNegative Malawian Populations.

Authors:  A C Crampin; F D Mwaungulu; L R Ambrose; H Longwe; N French
Journal:  Open AIDS J       Date:  2011-08-10

7.  Validation of a single-platform, volumetric, flow cytometry for CD4 T cell count monitoring in therapeutic mobile unit.

Authors:  François-Xavier Mbopi-Kéou; Bertrand Sagnia; Jeanne Ngogang; Fru F Angwafo; Vittorio Colizzi; Luc Montagnier; Laurent Bélec
Journal:  J Transl Med       Date:  2012-02-06       Impact factor: 5.531

8.  Single-platform, volumetric, CD45-assisted pan-leucogating flow cytometry for CD4 T lymphocytes monitoring of HIV infection according to the WHO recommendations for resource-constrained settings.

Authors:  Donato Koyalta; Mohammad-Ali Jenabian; Ngamasra Nadjiouroum; Barou Djouater; Noël Djemadji-Oudjeil; Angélique Ndjoyi-Mbiguino; Laurent Bélec
Journal:  BMC Res Notes       Date:  2013-04-30

9.  CD4 estimating reagents in dry format are compatible with conventional flow cytometer; FACSCalibur for estimation of absolute CD4 count & percentages.

Authors:  Madhuri Thakar; Bharati Mahajan; Trupti Joshi; Suvarna Sane; Ramesh Paranjape
Journal:  Indian J Med Res       Date:  2013-02       Impact factor: 2.375

10.  CD4 T-cell enumeration in a field setting: evaluation of CyFlow counter using the CD4 easy count kit-dry and Pima CD4 systems.

Authors:  Djibril Wade; Papa Alassane Diaw; Géraldine Daneau; Makhtar Camara; Tandakha Ndiaye Dieye; Souleymane Mboup; Luc Kestens
Journal:  PLoS One       Date:  2013-09-16       Impact factor: 3.240