Literature DB >> 15851220

Randomized prospective trial of atrioventricular delay programming for cardiac resynchronization therapy.

Navinder S Sawhney1, Alan D Waggoner, Sanjeev Garhwal, Mohit K Chawla, Judy Osborn, Mitchell N Faddis.   

Abstract

OBJECTIVES: The purpose of this study was to determine if AV delay optimization with continuous-wave Doppler aortic velocity-time integral (VTI) is clinically superior to an empiric program in patients treated with cardiac resynchronization therapy (CRT) for severe heart failure.
BACKGROUND: The impact of AV delay programming on clinical outcomes associated with CRT is unknown.
METHODS: A randomized, prospective, single-blind clinical trial was performed to compare two methods of AV delay programming in 40 patients with severe heart failure referred for CRT. Patients were randomized to either an optimized AV delay determined by Doppler echocardiography (group 1, n = 20) or an empiric AV delay of 120 ms (group 2, n = 20) with both groups programmed in the atriosynchronous biventricular pacing (VDD) mode. Optimal AV delay was defined as the AV delay that yielded the largest aortic VTI at one of eight tested AV intervals (between 60 and 200 ms). New York Heart Association (NYHA) functional classification and quality-of-life (QOL) score were compared 3 months after randomization.
RESULTS: Immediately after CRT initiation with AV delay programming, VTI improved by 4.0 +/- 1.7 cm vs 1.8 +/- 3.6 cm (P < .02), and ejection fraction (EF) increased by 7.8 +/- 6.2% vs 3.4 +/- 4.4% (P < .02) in group 1 vs group 2, respectively. After 3 months, NYHA classification improved by 1.0 +/- 0.5 vs 0.4 +/- 0.6 class points (P < .01), and QOL score improved by 23 +/- 13 versus 13 +/- 11 points (P < .03) for group 1 vs group 2, respectively.
CONCLUSIONS: Echocardiography-guided AV delay optimization using the aortic Doppler VTI improves clinical outcomes at 3 months compared to an empiric AV delay program of 120 ms.

Entities:  

Mesh:

Year:  2004        PMID: 15851220     DOI: 10.1016/j.hrthm.2004.07.006

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  34 in total

1.  Measurement precision in the optimization of cardiac resynchronization therapy.

Authors:  Robert G Turcott; Ronald M Witteles; Paul J Wang; Randall H Vagelos; Michael B Fowler; Euan A Ashley
Journal:  Circ Heart Fail       Date:  2010-02-22       Impact factor: 8.790

2.  Effect of atrioventricular conduction prolongation on optimization of paced atrioventricular delay for biventricular pacing after cardiac surgery.

Authors:  Alexander Rusanov; Daniel Y Wang; Santos E Cabreriza; Lauren N Bedrosian; Suzanne R Karl; Marc E Richmond; T Alexander Quinn; Bin Cheng; Henry M Spotnitz
Journal:  J Cardiothorac Vasc Anesth       Date:  2011-10-14       Impact factor: 2.628

3.  The search for optimal atrioventricular interval.

Authors:  I Eli Ovsyshcher
Journal:  J Interv Card Electrophysiol       Date:  2005-11       Impact factor: 1.900

4.  Haemodynamic effects of changes in atrioventricular and interventricular delay in cardiac resynchronisation therapy show a consistent pattern: analysis of shape, magnitude and relative importance of atrioventricular and interventricular delay.

Authors:  Z I Whinnett; J E R Davies; K Willson; C H Manisty; A W Chow; R A Foale; D Wyn Davies; A D Hughes; J Mayet; D P Francis
Journal:  Heart       Date:  2006-05-18       Impact factor: 5.994

Review 5.  Physiology of biventricular pacing.

Authors:  Kenneth C Bilchick; Robert H Helm; David A Kass
Journal:  Curr Cardiol Rep       Date:  2007-09       Impact factor: 2.931

6.  Optimization of cardiac resynchronization therapy after implantation.

Authors:  Ayesha Hasan; William T Abraham
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-08

7.  The impact of age on clinical outcomes following cardiac resynchronisation therapy.

Authors:  K Guha; D Konstantinou; L Mantziari; B N Modi; B Chandrasekaran; Z Khalique; T McDonagh; R Sharma
Journal:  J Interv Card Electrophysiol       Date:  2013-11-29       Impact factor: 1.900

8.  Effects of AV-delay optimization on hemodynamic parameters in patients with VDD pacemakers.

Authors:  Konstantin A Krychtiuk; Michael Nürnberg; Romana Volker; Linda Pachinger; Rudolf Jarai; Matthias K Freynhofer; Johann Wojta; Kurt Huber; Thomas W Weiss
Journal:  Wien Klin Wochenschr       Date:  2014-03-21       Impact factor: 1.704

Review 9.  State-of-the-art narrative review: multimodality imaging in electrophysiology and cardiac device therapies.

Authors:  Balint Laczay; Divyang Patel; Richard Grimm; Bo Xu
Journal:  Cardiovasc Diagn Ther       Date:  2021-06

Review 10.  Doppler echocardiographic methods for optimization of the atrioventricular delay during cardiac resynchronization therapy.

Authors:  Alan D Waggoner; Lisa de las Fuentes; Victor G Davila-Roman
Journal:  Echocardiography       Date:  2008-10       Impact factor: 1.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.