Cardiac resynchronization therapy in congestive heart failure: Ready for prime time?

Antonis S Manolis1.   

Abstract

OBJECTIVES/
BACKGROUND: The aim of this article is to critically review the data accumulated to date on the application of cardiac resynchronization therapy (CRT) via biventricular pacing techniques to manage patients with advanced heart failure. The data from studies evaluating the effects of long-term right ventricular (RV) pacing are also briefly reviewed.
METHODS: MEDLINE and selective journal searches of English-language reports and a search of references of relevant papers were conducted.
RESULTS: Cardiac dyssynchrony as reflected by a prolonged QRS complex, often in the form of left bundle branch block, is encountered in about 30% of patients with moderate-to-advanced heart failure. Among these patients, 10% to 15% are candidates for CRT via biventricular pacing. Accumulated evidence from randomized controlled studies over the last few years has indicated a significant hemodynamic and clinical improvement conferred by CRT to class III or IV heart failure patients with idiopathic or ischemic dilated cardiomyopathy having a low left ventricular ejection fraction (</=35%) and a wide QRS complex (>/=120-150 ms). Newer data suggest a significant reduction in overall mortality and heart failure hospitalization, particularly when CRT is combined with automatic defibrillator backup. Technical advances with percutaneous methods accessing the tributaries of the cardiac veins have raised the success rate of implantation of left ventricular leads to >90%. Further confirmation from ongoing trials is awaited, and more data from cost-effectiveness studies are needed before CRT is considered for prime time therapy in the heart failure population. If the data confirm a survival benefit from CRT, use of this electrical therapy at earlier stages of heart failure might be contemplated. New evidence from recent studies suggests a deleterious effect of the long-standing practice of producing an iatrogenic left bundle branch block by conventional RV apical pacing in patients receiving permanent pacemakers. Thus, having already become poignantly aware of the harmful effects of spontaneous left bundle branch block, this emerging new evidence about RV apical pacing would dictate a change of attitude and direct our attention to alternate sites of pacing, such as the left ventricle and/or the RV outflow tract, if not for all patients then at least for those with left ventricular dysfunction.
CONCLUSIONS: CRT offers hemodynamic and clinical improvement to patients with moderate-to-advanced heart failure, and it might significantly prolong survival in selected patients, particularly if devices with defibrillation backup are used. Further confirmatory data from randomized mortality trials are needed, and issues of cost efficacy must be resolved before this vital therapeutic alternative is ready for prime time therapy of heart failure patients.

Entities:  

Mesh:

Year:  2004        PMID: 15851184     DOI: 10.1016/j.hrthm.2004.03.065

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  6 in total

1.  [Phrenic nerve stimulation in biventricular cardiac pacemakers].

Authors:  T Schwierz; S Winter; H Pürerfellner; F Tomaselli; H-J Nesser; R Függer
Journal:  Chirurg       Date:  2007-11       Impact factor: 0.955

2.  Cardiac resynchronisation therapy and the role of optimal device utilisation.

Authors:  S Buck; A H Maass; D J van Veldhuisen; I C Van Gelder
Journal:  Neth Heart J       Date:  2009-09       Impact factor: 2.380

Review 3.  Cardiac resynchronization therapy: Dire need for targeted left ventricular lead placement and optimal device programming.

Authors:  Sokratis Pastromas; Antonis S Manolis
Journal:  World J Cardiol       Date:  2014-12-26

4.  "Real life" longevity of implantable cardioverter-defibrillator devices.

Authors:  Antonis S Manolis; Themistoklis Maounis; Spyridon Koulouris; Vassilios Vassilikos
Journal:  Clin Cardiol       Date:  2017-05-22       Impact factor: 2.882

5.  Correlation of mechanical dyssynchrony with QRS duration measured by signal-averaged electrocardiography.

Authors:  George K Andrikopoulos; Stylianos Tzeis; Christof Kolb; Dimitrios Sakellariou; Dimosthenes Avramides; Evangelos C Alexopoulos; Konstantinos Triantafyllou; Antonis S Manolis
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-07       Impact factor: 1.468

6.  Cardiac implantable electronic device lead extraction using the lead-locking device system: keeping it simple, safe, and inexpensive with mechanical tools and local anesthesia.

Authors:  Antonis S Manolis; Georgios Georgiopoulos; Sofia Metaxa; Spyridon Koulouris; Dimitris Tsiachris
Journal:  Anatol J Cardiol       Date:  2017-08-11       Impact factor: 1.596

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.