Literature DB >> 15847595

Kerr-gated time-resolved Raman spectroscopy of equine cortical bone tissue.

Michael D Morris1, Pavel Matousek, Michael Towrie, Anthony W Parker, Allen E Goodship, Edward R C Draper.   

Abstract

Picosecond time-resolved Raman spectroscopy in equine cortical bone tissue is demonstrated. Using 400-nm pulsed laser excitation (1 ps at 1 kHz) it is shown that Kerr cell gating with a 4-ps window provides simultaneously time-resolved rejection of fluorescence and time-resolved Raman scatter enabling depth profiling through tissue. The Raman shifts are the same as those observed by conventional cw Raman spectroscopy using deep-red or near-infrared lasers. The time decay of Raman photons is shown to fit an inverse square root of time function, suggesting propagation by a diffusive mechanism. Using polystyrene behind a bone specimen, it is shown that the 400-nm laser light penetrates at least 0.31 mm below the surface of a fully mineralized bone tissue specimen and generates observable bone Raman scatter (approximately 415 to 430 nm) through most of this depth. These novel results demonstrate great promise for in vivo applications for studying diseased bone tissue, and ways to optimize the setup are discussed. Copyright 2005 Society of Photo-Optical Instrumentation Engineers

Entities:  

Mesh:

Year:  2005        PMID: 15847595     DOI: 10.1117/1.1827605

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  9 in total

1.  Raman signal enhancement via elastic light scattering.

Authors:  Brett H Hokr; Vladislav V Yakovlev
Journal:  Opt Express       Date:  2013-05-20       Impact factor: 3.894

Review 2.  Emerging non-invasive Raman methods in process control and forensic applications.

Authors:  Neil A Macleod; Pavel Matousek
Journal:  Pharm Res       Date:  2008-04-16       Impact factor: 4.200

3.  Effect of photobleaching on calibration model development in biological Raman spectroscopy.

Authors:  Ishan Barman; Chae-Ryon Kong; Gajendra P Singh; Ramachandra R Dasari
Journal:  J Biomed Opt       Date:  2011 Jan-Feb       Impact factor: 3.170

4.  Repeated freeze-thawing of bone tissue affects Raman bone quality measurements.

Authors:  John-David P McElderry; Matthew R Kole; Michael D Morris
Journal:  J Biomed Opt       Date:  2011-07       Impact factor: 3.170

5.  Using Raman spectroscopy to characterize biological materials.

Authors:  Holly J Butler; Lorna Ashton; Benjamin Bird; Gianfelice Cinque; Kelly Curtis; Jennifer Dorney; Karen Esmonde-White; Nigel J Fullwood; Benjamin Gardner; Pierre L Martin-Hirsch; Michael J Walsh; Martin R McAinsh; Nicholas Stone; Francis L Martin
Journal:  Nat Protoc       Date:  2016-03-10       Impact factor: 13.491

6.  Automated Raman Spectral Preprocessing of Bone and Other Musculoskeletal Tissues.

Authors:  Francis W L Esmonde-White; Matthew V Schulmerich; Karen A Esmonde-White; Michael D Morris
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-02-18

Review 7.  Modulated Raman Spectroscopy for Enhanced Cancer Diagnosis at the Cellular Level.

Authors:  Anna Chiara De Luca; Kishan Dholakia; Michael Mazilu
Journal:  Sensors (Basel)       Date:  2015-06-11       Impact factor: 3.576

8.  In Vivo, Non-Invasive Characterization of Human Bone by Hybrid Broadband (600-1200 nm) Diffuse Optical and Correlation Spectroscopies.

Authors:  Sanathana Konugolu Venkata Sekar; Marco Pagliazzi; Eugènia Negredo; Fabrizio Martelli; Andrea Farina; Alberto Dalla Mora; Claus Lindner; Parisa Farzam; Núria Pérez-Álvarez; Jordi Puig; Paola Taroni; Antonio Pifferi; Turgut Durduran
Journal:  PLoS One       Date:  2016-12-20       Impact factor: 3.240

9.  Real-time In vivo Diagnosis of Nasopharyngeal Carcinoma Using Rapid Fiber-Optic Raman Spectroscopy.

Authors:  Kan Lin; Wei Zheng; Chwee Ming Lim; Zhiwei Huang
Journal:  Theranostics       Date:  2017-08-18       Impact factor: 11.556

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.