Literature DB >> 15845671

A comparison of the Vasotrac with invasive arterial blood pressure monitoring in children after pediatric cardiac surgery.

Clifford L Cua1, Kristi Thomas, David Zurakowski, Peter C Laussen.   

Abstract

The Vasotrac is a device that provides near-continuous and noninvasive arterial blood pressure monitoring and may be an alternative to direct intraarterial measurement. It has been evaluated in adult patients, but minimal information is available for pediatric patients. We evaluated agreement between measurements of arterial blood pressure and heart rate obtained from the Vasotrac versus an arterial catheter in a pediatric population. Children undergoing corrective cardiac surgery were enrolled. Simultaneous arterial blood pressure measurements were obtained postoperatively from the Vasotrac unit and an arterial catheter. Bland-Altman plots were constructed to assess agreement. Paired correlation analysis, bias, and precision calculations were performed. Sixteen patients, mean age 10.1 +/- 2.3 yr and weight 34.6 +/- 11.9 kg, were enrolled. Four-thousand-one- hundred- two paired measurements were obtained. Arterial blood pressures measured noninvasively correlated with catheter measurements with Pearson r values of 0.90, 0.80, and 0.91 for systolic, diastolic, and mean arterial blood pressures, respectively (all P < 0.001). There was excellent agreement between arterial blood pressure measurement methods. Absolute mean differences based on mixed-model regression with 95% confidence intervals were 4.0 mm Hg (3.0-5.0 mm Hg), 4.3 mm Hg (3.1-5.5 mm Hg), and 3.5 mm Hg (2.5-4.0 mm Hg) for systolic blood pressure, diastolic blood pressure, and mean blood pressure, respectively. Arterial blood pressure measurements obtained from the Vasotrac agreed well with invasive arterial monitoring in pediatric patients.

Entities:  

Mesh:

Year:  2005        PMID: 15845671     DOI: 10.1213/01.ANE.0000149591.67207.05

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  6 in total

Review 1.  Orthostatic hypotension: framework of the syndrome.

Authors:  Jochanan E Naschitz; Itzhak Rosner
Journal:  Postgrad Med J       Date:  2007-09       Impact factor: 2.401

2.  A comparison of noninvasive blood pressure measurement on the wrist with invasive arterial blood pressure monitoring in patients undergoing bariatric surgery.

Authors:  Helmut Hager; Goutham Mandadi; Debra Pulley; J Chris Eagon; Edward Mascha; Benjamin Nutter; Andrea Kurz
Journal:  Obes Surg       Date:  2008-07-10       Impact factor: 4.129

3.  Sex-specific programming of cardiovascular physiology in children.

Authors:  Alexander Jones; Alessandro Beda; Clive Osmond; Keith M Godfrey; David M Simpson; David I W Phillips
Journal:  Eur Heart J       Date:  2008-07-22       Impact factor: 29.983

4.  Noninvasive techniques for blood pressure measurement are not a reliable alternative to direct measurement: a randomized crossover trial in ICU.

Authors:  Sara Ribezzo; Eleonora Spina; Stefano Di Bartolomeo; Gianfranco Sanson
Journal:  ScientificWorldJournal       Date:  2014-01-30

5.  Tissue-informative mechanism for wearable non-invasive continuous blood pressure monitoring.

Authors:  Sung Hun Woo; Yun Young Choi; Dae Jung Kim; Franklin Bien; Jae Joon Kim
Journal:  Sci Rep       Date:  2014-10-21       Impact factor: 4.379

6.  Non-invasive monitoring of blood pressure using the Philips Intellivue MP50 monitor cannot replace invasive blood pressure techniques in surgery patients under general anesthesia.

Authors:  Xianghu Meng; Guanghui Zang; Longchang Fan; Lei Zheng; Jinzhen Dai; Xueren Wang; Wei Xia; Jihong Liu; Chuanhan Zhang
Journal:  Exp Ther Med       Date:  2013-05-17       Impact factor: 2.447

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.