BACKGROUND: A new diamond-coated ultrasonic insert has been developed for scaling and root planing, and it was evaluated in vitro for the amount of root surface removed and the roughness of the residual root surface as a result of instrumentation.
METHODS: 48 extracted single-rooted human teeth were ground flat on one root surface and mounted (flat side up) in PVC rings of standard height and diameter with improved dental stone. Each tooth surface was treated with either a plain ultrasonic insert (PI), an ultrasonic insert with a fine grit diamond coating (DI) or sharp Gracey curettes (HI). The mounted teeth were attached to a stepper motor which drove the teeth in a horizontal, reciprocal motion at a constant rate. The thickness from the flattened bottom of the ring to the flattened tooth surface was measured before and after 10, 20, and 30 instrumentation strokes for each root surface with each of the experimental instruments. A number of treated teeth were randomly selected for examination with SEM and a profilometer. Statistical analysis (analysis of co-variance) was performed to compare the amounts of tooth structure removed among the 3 instruments and t-test was used to compare the roughness of the treated root surfaces.
RESULTS: The mean depth of root structure removed was PI 10.7 microm, HI 15.0 microm, and DI 46.2 microm after 10 strokes; and PI 21.6 microm, HI 33.2 and DI 142.0 microm after 30 strokes, respectively. On average, 0.9 microm, 1.3 microm, and 4.7 microm of root surface was removed with each stroke of PI, HI and DI, respectively. PI and HI were not different from each other for all the stroke cycles, while DI was significantly different from PI and HI for all the stroke cycles (p<0.0001). Analysis with the profilometer showed that the smoothest surface was produced by the PI followed by the HI. The DI produced a surface that was significantly rougher than the surface produced by the PI or HI.
CONCLUSION: These results suggest that diamond-coated ultrasonic instruments will effectively plane roots, and that caution should be used during periodontal root planing procedures. Additionally, the diamond-coated instruments will produce a rougher surface than the plain inserts or the hand curettes.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15842261     DOI: 10.1111/j.1600-051X.2005.00705.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  8 in total

1.  Comparison of Root Surface Roughness Produced By Hand Instruments and Ultrasonic Scalers: An Invitro Study.

Authors:  Pawan Kumar; Swarga Jyoti Das; Saindhya Tora Sonowal; Jitendra Chawla
Journal:  J Clin Diagn Res       Date:  2015-11-01

2.  Effects of Root Debridement With Hand Curettes and Er:YAG Laser on Chemical Properties and Ultrastructure of Periodontally-Diseased Root Surfaces Using Spectroscopy and Scanning Electron Microscopy.

Authors:  Reza Amid; Gholam Ali Gholami; Masoud Mojahedi; Maryam Aghalou; Mohsen Gholami; Mahdieh Mirakhori
Journal:  J Lasers Med Sci       Date:  2017-03-28

3.  Analysis of the effects of air polishing powders containing sodium bicarbonate and glycine on human teeth.

Authors:  Julia Bühler; Fredy Schmidli; Roland Weiger; Clemens Walter
Journal:  Clin Oral Investig       Date:  2014-09-21       Impact factor: 3.573

4.  In vitro adhesion of Streptococcus sanguinis to dentine root surface after treatment with Er:YAG laser, ultrasonic system, or manual curette.

Authors:  Claudia Ota-Tsuzuki; Fernanda L Martins; Ana Paula O Giorgetti; Patrícia M de Freitas; Poliana M Duarte
Journal:  Photomed Laser Surg       Date:  2009-10       Impact factor: 2.796

5.  Efficacy versus health risks: An in vitro evaluation of power-driven scalers.

Authors:  Christian Graetz; Anna Plaumann; Jule Bielfeldt; Anica Tillner; Sonja Sälzer; Christof Edmund Dörfer
Journal:  J Indian Soc Periodontol       Date:  2015 Jan-Feb

6.  The effect of various ultrasonic and hand instruments on the root surfaces of human single rooted teeth: A Planimetric and Profilometric study.

Authors:  Antush Mittal; Ashish Sham Nichani; Ranganath Venugopal; Vuppalapati Rajani
Journal:  J Indian Soc Periodontol       Date:  2014 Nov-Dec

7.  Substrate roughness induces the development of defective E-cadherin junctions in human gingival keratinocytes.

Authors:  Chengbiao Jin; Gayoung Lee; Changseok Oh; Hyun Jung Kim; Hyun-Man Kim
Journal:  J Periodontal Implant Sci       Date:  2017-04-29       Impact factor: 2.614

8.  Clinical and microbiological effects of the supplementary use of an erythritol powder air-polishing device in non-surgical periodontal therapy: a randomized clinical trial.

Authors:  Eon-Jeong Park; Eun-Young Kwon; Hyun-Joo Kim; Ju-Youn Lee; Jeomil Choi; Ji-Young Joo
Journal:  J Periodontal Implant Sci       Date:  2018-10-24       Impact factor: 2.614

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.