Beam characteristics of a new model of 6-MV linear accelerator.

D P Fontenla1, J J Napoli, C S Chui.   

Abstract

This paper describes the beam characteristics and dosimetry measurements performed on the 6-MV photon beam of a new model of linear accelerator, three of which were recently introduced and installed in our institution. Percent depth dose and tissue maximum ratio tables for a variety of field sizes and depths, as well as other parameters used for treatment planning are presented. These accelerators are the first of their kind using both hardware and software tools to control interlocks. Checking procedures for these interlocks are available from the authors upon request. Comparison of characteristic parameters between these three new 6-MV linear accelerators and with the 6-MV beams of two other accelerators is also made.

Mesh:

Year:  1992        PMID: 1584128     DOI: 10.1118/1.596864

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  A mathematical approach to beam matching.

Authors:  B Sarkar; A Manikandan; M Nandy; M S Gossman; C S Sureka; A Ray; N Sujatha
Journal:  Br J Radiol       Date:  2013-08-30       Impact factor: 3.039

2.  Technical Report: Reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data.

Authors:  James R Kerns; David S Followill; Jessica Lowenstein; Andrea Molineu; Paola Alvarez; Paige A Taylor; Francesco C Stingo; Stephen F Kry
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

3.  Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations.

Authors:  Scott E Davidson; Jing Cui; Stephen Kry; Joseph O Deasy; Geoffrey S Ibbott; Milos Vicic; R Allen White; David S Followill
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

4.  Agreement Between Institutional Measurements and Treatment Planning System Calculations for Basic Dosimetric Parameters as Measured by the Imaging and Radiation Oncology Core-Houston.

Authors:  James R Kerns; David S Followill; Jessica Lowenstein; Andrea Molineu; Paola Alvarez; Paige A Taylor; Stephen F Kry
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-04-02       Impact factor: 7.038

5.  AAPM Medical Physics Practice Guideline 5.a.: Commissioning and QA of Treatment Planning Dose Calculations - Megavoltage Photon and Electron Beams.

Authors:  Jennifer B Smilowitz; Indra J Das; Vladimir Feygelman; Benedick A Fraass; Stephen F Kry; Ingrid R Marshall; Dimitris N Mihailidis; Zoubir Ouhib; Timothy Ritter; Michael G Snyder; Lynne Fairobent
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.