Literature DB >> 1584119

A method of calculating peripheral dose distributions of photon beams below 10 MV.

B J McParland1, H I Fair.   

Abstract

The radiation dose outside the radiotherapy treatment field can be of clinical concern and, therefore, a method of accurately predicting the peripheral doses received by tissues would be beneficial. This paper describes a semiempirical method developed for calculating the peripheral dose received at points outside the collimated field edge for incident photon beams with energies below neutron production thresholds (less than 10 MV). The dependence of the peripheral dose upon depth, distance, field shape and size, azimuthal angle about the central axis, external contour variations, and tissue heterogeneities are accounted for by this calculation. Predictions by this algorithm are compared with measurements and it is shown that the method is capable of reproducing the measured peripheral dose values usually to within the statistical uncertainties of the data.

Mesh:

Year:  1992        PMID: 1584119     DOI: 10.1118/1.596858

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Estimation of peripheral dose from Co60 beam in water phantom measured in Secondary Standard Dosimetry Laboratory, Pakistan.

Authors:  Muhammad Shahban; Babar Hussain; Khalid Mehmood; Shakeel Ur Rehman
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-21

2.  Peripheral dose measurement in high-energy photon radiotherapy with the implementation of MOSFET.

Authors:  Vassiliki Vlachopoulou; Georgia Malatara; Harry Delis; Kiki Theodorou; Dimitrios Kardamakis; George Panayiotakis
Journal:  World J Radiol       Date:  2010-11-28

3.  Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques.

Authors:  Jihyung Yoon; David Heins; Xiaodong Zhao; Mary Sanders; Rui Zhang
Journal:  Phys Med Biol       Date:  2017-11-13       Impact factor: 3.609

Review 4.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

5.  Reduction in stray radiation dose using a body-shielding device during external radiation therapy.

Authors:  Shuxu Zhang; Shaohui Jiang; Quanbin Zhang; Shengqu Lin; Ruihao Wang; Xiang Zhou; Guoqian Zhang; Huaiyu Lei; Hui Yu
Journal:  J Appl Clin Med Phys       Date:  2017-02-02       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.