Literature DB >> 15837255

Safety of dobutamine stress real-time myocardial contrast echocardiography.

Jeane M Tsutsui1, Abdou Elhendy, Feng Xie, Edward L O'Leary, Anna C McGrain, Thomas R Porter.   

Abstract

OBJECTIVES: The aim of this study was to determine the safety of dobutamine stress myocardial perfusion imaging (MPI) obtained by real-time contrast echocardiography (RTCE) and intravenous ultrasound contrast in a large cohort of patients with suspected coronary artery disease (CAD).
BACKGROUND: Despite the increasing number of studies showing the potential clinical utility of myocardial contrast perfusion imaging with commercially available contrast agents, the safety of this technique in a clinical setting has not been demonstrated.
METHODS: Over a four-year period, 1,486 patients underwent dobutamine stress RTCE with low mechanical index pulse sequence schemes after intravenous injections of commercially available contrast agents (35% Definity, Bristol Myers Squibb Medical Imaging Inc., North Billerica, Massachusetts; 65% Optison, GE-Amersham, Princeton, New Jersey). The hemodynamic and adverse effects of RTCE were compared with 1,012 patients who underwent conventional dobutamine stress echocardiography (DSE) without contrast. The feasibility of image analysis was defined as the ability to analyze MPI in at least two of the three standard segments in each left ventricular wall.
RESULTS: No myocardial infarction or death occurred during dobutamine stress. There was no difference in the incidence of nonsustained ventricular tachycardia, sustained ventricular tachycardia, or supraventricular tachycardia during dobutamine infusion between RTCE and DSE. Myocardial perfusion imaging was considered feasible for analysis in 94% of the walls at baseline and 95% at peak stress. The anterior, lateral, and posterior walls were the most common regions in which MPI was not feasible. Myocardial perfusion imaging with RTCE had a higher accuracy for detecting patients with angiographically significant CAD than the analysis of wall motion (84% vs. 66%, respectively; p < 0.001).
CONCLUSIONS: Dobutamine stress RTCE appears to be a safe and feasible technique for evaluating patients with known or suspected CAD.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15837255     DOI: 10.1016/j.jacc.2005.01.024

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  17 in total

Review 1.  Contrast echocardiography: an update.

Authors:  Rajesh K Chelliah; Roxy Senior
Journal:  Curr Cardiol Rep       Date:  2009-05       Impact factor: 2.931

2.  (31)P cardiac magnetic resonance spectroscopy during leg exercise at 3 Tesla.

Authors:  Lucy E Hudsmith; Damian J Tyler; Yaso Emmanuel; Steffen E Petersen; Jane M Francis; Hugh Watkins; Kieran Clarke; Matthew D Robson; Stefan Neubauer
Journal:  Int J Cardiovasc Imaging       Date:  2009-08-21       Impact factor: 2.357

Review 3.  Stress echocardiography for the detection and assessment of coronary artery disease.

Authors:  Nowell M Fine; Patricia A Pellikka
Journal:  J Nucl Cardiol       Date:  2011-05       Impact factor: 5.952

Review 4.  Assessment of myocardial perfusion with real-time myocardial contrast echocardiography: methodology and clinical applications.

Authors:  Abdou Elhendy; Thomas R Porter
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

5.  Low Cost Magnetic Resonance Imaging-Compatible Stepper Exercise Device for Use in Cardiac Stress Tests.

Authors:  Omid Forouzan; Evan Flink; Jared Warczytowa; Nick Thate; Andrew Hanske; Tongkeun Lee; Alejandro Roldan-Alzate; Chris François; Oliver Wieben; Naomi C Chesler
Journal:  J Med Device       Date:  2014-08-19       Impact factor: 0.582

6.  Evaluation of restenosis and extent of coronary artery disease in patients with previous percutaneous coronary interventions by dobutamine stress real-time myocardial contrast perfusion imaging.

Authors:  A Elhendy; J M Tsutsui; E L O'Leary; F Xie; F Majeed; T R Porter
Journal:  Heart       Date:  2006-04-10       Impact factor: 5.994

7.  Dobutamine stress MRI versus threedimensional contrast echocardiography: It's all Black and White.

Authors:  A Nemes; M L Geleijnse; R-J van Geuns; O I I Soliman; W B Vletter; B J Krenning; F J Ten Cate
Journal:  Neth Heart J       Date:  2008-06       Impact factor: 2.380

8.  Incremental value of contrast myocardial perfusion to detect intermediate versus severe coronary artery stenosis during stress-echocardiography.

Authors:  Nicola Gaibazzi; Fausto Rigo; Angelo Squeri; Fabrizio Ugo; Claudio Reverberi
Journal:  Cardiovasc Ultrasound       Date:  2010-05-06       Impact factor: 2.062

9.  Stress echocardiography with contrast for the diagnosis of coronary artery disease: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-06-01

10.  Contrast echocardiography in Canada: Canadian Cardiovascular Society/Canadian Society of Echocardiography position paper.

Authors:  George Honos; Robert Amyot; Jonathan Choy; Howard Leong-Poi; Greg Schnell; Eric Yu
Journal:  Can J Cardiol       Date:  2007-04       Impact factor: 5.223

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.