Literature DB >> 15831556

The reproducibility and sensitivity of the 6-min walk test in elderly patients with chronic heart failure.

Lee Ingle1, Rhidian J Shelton, Alan S Rigby, Samantha Nabb, Andrew L Clark, John G F Cleland.   

Abstract

AIMS: The 6-min walk test (6-MWT) is used to estimate functional capacity. However, in elderly patients with chronic heart failure (CHF): (i) 1 year reproducibility of the 6-MWT; (ii) sensitivity of the 6-MWT to self-perceived changes in symptoms of heart failure; and (iii) implications for patient numbers required for studies using the 6-MWT as an endpoint have not been described. METHODS AND
RESULTS: One thousand and seventy-seven patients with CHF, aged>60, with NYHA Class > or =II were recruited. Heart failure symptom assessment was determined using a questionnaire related to aspects of physical function, and patients performed a baseline 6-MWT, with follow-up 1 year later. Seventy-four patients with unchanged symptoms had an unchanged 6-MWT distance, with an overall intraclass correlation coefficient of 0.80 (95% CI=0.69-0.87). Four hundred and twenty-three patients reported an improvement in symptoms during follow-up. There was a negative correlation (r=-0.55; P=0.0001) between Delta symptoms and Delta 6-MWT (i.e. a reduced 6-MWT distance is associated with reduced symptom severity at follow-up). Five hundred and sixteen patients reported worsening symptoms of heart failure, a moderate inverse correlation (r=-0.53; P=0.0001) was displayed between Delta symptoms and Delta 6-MWT. For all patients, irrespective of symptom status, a high inverse correlation (r=-0.75; P=0.0001) was evident. On the basis of the data for patients with unchanged symptoms, it is calculated that to detect an increase in 6-MWT of 50 m, with 90% power, a study size of approximately 120 is required.
CONCLUSION: In elderly patients with CHF, the 6-MWT shows satisfactory agreement when repeated 1 year later. Change in 6-MWT distance is sensitive to change in self-perceived symptoms of heart failure.

Entities:  

Mesh:

Year:  2005        PMID: 15831556     DOI: 10.1093/eurheartj/ehi259

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  34 in total

1.  Case report: exercise in a patient with acute decompensated heart failure receiving positive inotropic therapy.

Authors:  Ricard Paul E H; Robert Camarda; Laura Little Foley; Michael M Givertz; Lawrence P Cahalin
Journal:  Cardiopulm Phys Ther J       Date:  2011-06

2.  Clinically meaningful change estimates for the six-minute walk test and daily activity in individuals with chronic heart failure.

Authors:  Michael J Shoemaker; Amy B Curtis; Eric Vangsnes; Michael G Dickinson
Journal:  Cardiopulm Phys Ther J       Date:  2013-09

Review 3.  Origin of symptoms in chronic heart failure.

Authors:  A L Clark
Journal:  Heart       Date:  2005-09-13       Impact factor: 5.994

Review 4.  Six-Minute Walk Test for Assessing Physical Functional Capacity in Chronic Heart Failure.

Authors:  Huiyun Du; Parichat Wonggom; Jintana Tongpeth; Robyn A Clark
Journal:  Curr Heart Fail Rep       Date:  2017-06

5.  Weight lifting in patients with lower-extremity lymphedema secondary to cancer: a pilot and feasibility study.

Authors:  Elana Katz; Nicole L Dugan; Joy C Cohn; Christina Chu; Rebecca G Smith; Kathryn H Schmitz
Journal:  Arch Phys Med Rehabil       Date:  2010-07       Impact factor: 3.966

6.  Calcium Upregulation by Percutaneous Administration of Gene Therapy in Cardiac Disease (CUPID): a phase 2 trial of intracoronary gene therapy of sarcoplasmic reticulum Ca2+-ATPase in patients with advanced heart failure.

Authors:  Mariell Jessup; Barry Greenberg; Donna Mancini; Thomas Cappola; Daniel F Pauly; Brian Jaski; Alex Yaroshinsky; Krisztina M Zsebo; Howard Dittrich; Roger J Hajjar
Journal:  Circulation       Date:  2011-06-27       Impact factor: 29.690

7.  Physical Inactivity Predicts Slow Gait Speed in an Elderly Multi-Ethnic Cohort Study: The Northern Manhattan Study.

Authors:  Joshua Z Willey; Yeseon P Moon; Erin R Kulick; Ying Kuen Cheung; Clinton B Wright; Ralph L Sacco; Mitchell S V Elkind
Journal:  Neuroepidemiology       Date:  2017-08-16       Impact factor: 3.282

8.  Triangulating Clinically Meaningful Change in the Six-minute Walk Test in Individuals with Chronic Heart Failure: A Systematic Review.

Authors:  Michael J Shoemaker; Amy B Curtis; Eric Vangsnes; Michael G Dickinson
Journal:  Cardiopulm Phys Ther J       Date:  2012-09

9.  Accuracy and Usability of a Self-Administered 6-Minute Walk Test Smartphone Application.

Authors:  Gabriel C Brooks; Eric Vittinghoff; Sivaraman Iyer; Damini Tandon; Peter Kuhar; Kristine A Madsen; Gregory M Marcus; Mark J Pletcher; Jeffrey E Olgin
Journal:  Circ Heart Fail       Date:  2015-08-17       Impact factor: 8.790

Review 10.  What is treatment success in cardiac resynchronization therapy?

Authors:  Paul W X Foley; Francisco Leyva; Michael P Frenneaux
Journal:  Europace       Date:  2009-11       Impact factor: 5.214

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.