Literature DB >> 1583014

Three-dimensional kinematics of the human knee during walking.

M A Lafortune1, P R Cavanagh, H J Sommer, A Kalenak.   

Abstract

Three-dimensional kinematics of the tibiofemoral joint were studied during normal walking. Target markers were fixed to tibia and femur by means of intra-cortical traction pins. Radiographs of the lower limb were obtained to compute the position of the target markers relative to internal anatomical structures. High-speed cine cameras were used to measure three-dimensional coordinates of the target markers in five subjects walking at a speed of 1.2 m s-1. Relative motion between tibia and femur was resolved according to a joint coordinate system (JCS). The measurements have identified that substantial angular and linear motions occur about and along each of the JCS axes during walking. The results do not, however, support the traditional view that the so-called 'screw home' mechanism of the knee joint operates during gait.

Entities:  

Mesh:

Year:  1992        PMID: 1583014     DOI: 10.1016/0021-9290(92)90254-x

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  96 in total

1.  Weight-bearing knee kinematics in subjects with two types of anterior cruciate ligament reconstructions.

Authors:  Izumi Kanisawa; Anne Z Banks; Scott A Banks; Hideshige Moriya; Akihiro Tsuchiya
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2002-12-18       Impact factor: 4.342

2.  Methodological concerns using intra-cortical pins to measure tibiofemoral kinematics.

Authors:  D K Ramsey; P F Wretenberg; D L Benoit; M Lamontagne; G Németh
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-07-04       Impact factor: 4.342

3.  Comparison of wear in a total knee replacement under different kinematic conditions.

Authors:  P I Barnett; J Fisher; D D Auger; M H Stone; E Ingham
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

4.  Can hip and knee kinematics be improved by eliminating thigh markers?

Authors:  Brian W Schulz; Wendy L Kimmel
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-05-20       Impact factor: 2.063

5.  In vivo kinematics of the ACL-deficient limb during running and cutting.

Authors:  J C Waite; D J Beard; C A F Dodd; D W Murray; H S Gill
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-04-13       Impact factor: 4.342

6.  Dynamic knee motion in anterior cruciate impairment: a report and case study.

Authors:  Prashant Komdeur; Fabian E Pollo; Robert W Jackson
Journal:  Proc (Bayl Univ Med Cent)       Date:  2002-07

7.  Primary and secondary restraints of human and ovine knees for simulated in vivo gait kinematics.

Authors:  Rebecca J Nesbitt; Safa T Herfat; Daniel V Boguszewski; Andrew J Engel; Marc T Galloway; Jason T Shearn
Journal:  J Biomech       Date:  2013-11-25       Impact factor: 2.712

8.  Confirmation of long-term in vivo bearing mobility in eight rotating-platform TKAs.

Authors:  Michael T LaCour; Adrija Sharma; Christopher B Carr; Richard D Komistek; Douglas A Dennis
Journal:  Clin Orthop Relat Res       Date:  2014-04-26       Impact factor: 4.176

9.  Prediction and Validation of Load-Dependent Behavior of the Tibiofemoral and Patellofemoral Joints During Movement.

Authors:  Rachel L Lenhart; Jarred Kaiser; Colin R Smith; Darryl G Thelen
Journal:  Ann Biomed Eng       Date:  2015-04-28       Impact factor: 3.934

10.  Using relative velocity vectors to reveal axial rotation about the medial and lateral compartment of the knee.

Authors:  William J Anderst; Scott Tashman
Journal:  J Biomech       Date:  2009-12-14       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.