Literature DB >> 15826089

Electrical conductivity of ferritin proteins by conductive AFM.

Degao Xu1, Gerald D Watt, John N Harb, Robert C Davis.   

Abstract

Electrical conductivity measurements were performed on single apoferritin and holoferritin molecules by conductive atomic force microscopy. Conductivity of self-assembled monolayer films of ferritin molecules on gold surfaces was also measured. Holoferritin was 5-15 times more conductive than apoferritin, indicating that for holoferritin most electron-transfer goes through the ferrihydrite core. With 1 V applied, the average electrical currents through single holoferritin and apoferritin molecules were 2.6 pA and 0.19 pA, respectively.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15826089     DOI: 10.1021/nl048218x

Source DB:  PubMed          Journal:  Nano Lett        ISSN: 1530-6984            Impact factor:   11.189


  11 in total

1.  A protein transistor made of an antibody molecule and two gold nanoparticles.

Authors:  Yu-Shiun Chen; Meng-Yen Hong; G Steven Huang
Journal:  Nat Nanotechnol       Date:  2012-02-26       Impact factor: 39.213

2.  Scanning probe microscopy: Taking a closer look at conductivity.

Authors:  Julie V Macpherson
Journal:  Nat Nanotechnol       Date:  2011-02       Impact factor: 39.213

3.  Self-assembled enzymatic monolayer directly bound to a gold surface: activity and molecular recognition force spectroscopy studies.

Authors:  Lindsay R Ditzler; Arundhuti Sen; Michael J Gannon; Amnon Kohen; Alexei V Tivanski
Journal:  J Am Chem Soc       Date:  2011-08-04       Impact factor: 15.419

4.  Ferritin-Based Single-Electron Devices.

Authors:  Jacqueline A Labra-Muñoz; Arie de Reuver; Friso Koeleman; Martina Huber; Herre S J van der Zant
Journal:  Biomolecules       Date:  2022-05-15

5.  AFM of biological complexes: what can we learn?

Authors:  Maria Gaczynska; Pawel A Osmulski
Journal:  Curr Opin Colloid Interface Sci       Date:  2008-10       Impact factor: 6.448

6.  Fast, exact, and non-destructive diagnoses of contact failures in nano-scale semiconductor device using conductive AFM.

Authors:  ChaeHo Shin; Kyongjun Kim; JeongHoi Kim; Wooseok Ko; Yusin Yang; SangKil Lee; Chung Sam Jun; Youn Sang Kim
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

7.  Applications of chitosan (CHI)-reduced graphene oxide (rGO)-polyaniline (PAni) conducting composite electrode for energy generation in glucose biofuel cell.

Authors:  Sufia Ul Haque; Abu Nasar; Mohammed Muzibur Rahman
Journal:  Sci Rep       Date:  2020-06-26       Impact factor: 4.379

Review 8.  Piezoelectric Peptide and Metabolite Materials.

Authors:  Hui Yuan; Peipei Han; Kai Tao; Shuhai Liu; Ehud Gazit; Rusen Yang
Journal:  Research (Wash D C)       Date:  2019-11-21

9.  How stable are the collagen and ferritin proteins for application in bioelectronics?

Authors:  Jayeeta Kolay; Sudipta Bera; Rupa Mukhopadhyay
Journal:  PLoS One       Date:  2021-01-29       Impact factor: 3.240

Review 10.  Current Technical Approaches for the Early Detection of Foodborne Pathogens: Challenges and Opportunities.

Authors:  Il-Hoon Cho; Seockmo Ku
Journal:  Int J Mol Sci       Date:  2017-09-30       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.