Literature DB >> 15821639

Three-dimensional echocardiography improves the understanding of left atrioventricular valve morphology and function in atrioventricular septal defects undergoing patch augmentation.

Catherine Barrea1, Stéphanie Levasseur, Kevin Roman, Masaki Nii, John G Coles, William G Williams, Jeffrey F Smallhorn.   

Abstract

OBJECTIVES: We sought to address the role of 3-dimensional echocardiography in the evaluation of the left atrioventricular valve in children with an atrioventricular septal defect who underwent patch augmentation of their valve for either regurgitation or left ventricular outflow tract obstruction.
METHODS: Five children whose ages ranged between 4.5 and 9.2 years and who underwent patch augmentation of their left atrioventricular valve had a preoperative and postoperative transesophageal echocardiogram with 3-dimensional reconstruction to evaluate the left atrioventricular valve. The indication for operation was left atrioventricular valve regurgitation in 3 patients and left ventricular outflow tract obstruction in 2 patients. Three were rerepairs, and 2 were primary repairs. Both 3-dimensional morphology and color Doppler data were obtained. Two- and 3-dimensional findings were correlated with surgical observations through the use of direct inspection and video images obtained with a head-mounted super-VHS camera.
RESULTS: In each case there was precise correlation between the 3-dimensional and surgical findings as to the cause of leaflet failure in those with regurgitation. The site that would require leaflet augmentation could be determined by means of 3-dimensional echocardiography. Three-dimensional echocardiography provided more specific detail as to the morphology and function of the left atrioventricular valve than did its 2-dimensional counterpart.
CONCLUSIONS: Three-dimensional echocardiography provides detailed information about the status of the left atrioventricular valve in the atrioventricular septal defect and can aid in the planning of either primary or secondary repair.

Entities:  

Mesh:

Year:  2005        PMID: 15821639     DOI: 10.1016/j.jtcvs.2004.07.023

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  7 in total

1.  Quantification of mitral valve apparatus by three-dimensional transesophageal echocardiography: in vitro validation study comparing two different analysis systems.

Authors:  Ken Saito; Hiroyuki Okura; Nozomi Watanabe; Koichiro Imai; Tomoko Tamada; Terumasa Koyama; Akihiro Hayashida; Yoji Neishi; Takahiro Kawamoto; Kiyoshi Yoshida
Journal:  J Echocardiogr       Date:  2011-05-21

2.  Usefulness of the multiplanar reformatting mode of three-dimensional echocardiography in evaluating valvular and structural heart disease: An experience from Saudi Arabia.

Authors:  Saad Q Khoshhal
Journal:  J Saudi Heart Assoc       Date:  2013-11-13

Review 3.  Feasibility and effectiveness of three-dimensional echocardiography in diagnosing congenital heart diseases.

Authors:  Saad Khoshhal
Journal:  Pediatr Cardiol       Date:  2013-05-16       Impact factor: 1.655

Review 4.  "Repair of common atrioventricular junction in isolation and when associated with other congenital heart defects".

Authors:  Neville Abel George Solomon; Musthafa Janeel; Swaminathan Vaidyanathan
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2020-06-11

5.  Congenital mitral valve lesions : Correlation between morphology and imaging.

Authors:  Bo Remenyi; Tom L Gentles
Journal:  Ann Pediatr Cardiol       Date:  2012-01

6.  Mitral valve operations at a high-volume pediatric heart center: Evolving techniques and improved survival with mitral valve repair versus replacement.

Authors:  Christopher W Baird; Patrick O Myers; Gerald Marx; Pedro J Del Nido
Journal:  Ann Pediatr Cardiol       Date:  2012-01

7.  An adult case of single atrium diagnosed using three-dimensional echocardiography.

Authors:  Bernas Altıntaş; Barış Yaylak; Erkan Baysal
Journal:  Anatol J Cardiol       Date:  2017-06       Impact factor: 1.596

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.