Literature DB >> 1582140

Non-invasive vs. invasive beat-to-beat monitoring of blood pressure.

A Gabriel1, L E Lindblad, C Angleryd.   

Abstract

The present study focuses on the accuracy in tracing fast beat-to-beat changes in blood pressure using a non-invasive technique. The measurements using a commercially available apparatus (Finapres, Ohmeda, USA) were compared to ipsilateral intra-arterial radial pressure. Eight patients were studied at rest, during deep breathing with a fixed rate of 6 breaths min-1, and during an exercise test on an ergometer cycle. A total of 900 systolic pressure values were included for statistical evaluation, covering a pressure range of 86-266 mmHg. On average the systolic correlation coefficient for the whole material was 0.97, with a range of 0.94-0.996. For mean pressure the correlation coefficient was on average 0.97, and for diastolic pressure 0.93. No systematic difference between the non-invasive and the invasive method was found, although for each individual patient a difference between direct and indirect measured blood pressure existed that could be relatively large (systolic pressure: average difference = 0.8 mmHg, SD = 16 mmHg). We found the method easy to handle and consider it excellently suited to track relative changes in blood pressure.

Entities:  

Mesh:

Year:  1992        PMID: 1582140     DOI: 10.1111/j.1475-097x.1992.tb00309.x

Source DB:  PubMed          Journal:  Clin Physiol        ISSN: 0144-5979


  6 in total

1.  Evaluation of noninvasive blood pressure recording by photoplethysmography in clinical studies using angiotensin challenges.

Authors:  T Buclin; C Buchwalder-Csajka; H R Brunner; J Biollaz
Journal:  Br J Clin Pharmacol       Date:  1999-10       Impact factor: 4.335

2.  Continuous mean arterial pressure measurement in the fingers: the influence of local arm cooling.

Authors:  R Raamat; K Jagomägi; J Talts; E Länsimies; J Jurvelin; P Kolari
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

3.  Population pharmacokinetic-pharmacodynamic modelling of angiotensin receptor blockade in healthy volunteers.

Authors:  Chantal Csajka; Thierry Buclin; Karin Fattinger; Hans R Brunner; Jérôme Biollaz
Journal:  Clin Pharmacokinet       Date:  2002       Impact factor: 6.447

4.  Beta-adrenergic receptor desensitization in man: insight into post-exercise attenuation of cardiac function.

Authors:  Emma Hart; Ellen Dawson; Peter Rasmussen; Keith George; Niels H Secher; Greg Whyte; Rob Shave
Journal:  J Physiol       Date:  2006-09-14       Impact factor: 5.182

5.  A poor correlation exists between oscillometric and radial arterial blood pressure as measured by the Philips MP90 monitor.

Authors:  Samuel A Mireles; Richard A Jaffe; David R Drover; John G Brock-Utne
Journal:  J Clin Monit Comput       Date:  2009-04-25       Impact factor: 2.502

6.  Characterizing sympathetic neurovascular transduction in humans.

Authors:  Can Ozan Tan; Renaud Tamisier; J W Hamner; J Andrew Taylor
Journal:  PLoS One       Date:  2013-01-10       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.