The ProSeal laryngeal mask airway and the laryngeal tube Suction for ventilation in gynaecological patients undergoing laparoscopic surgery.

H Roth1, H V Genzwuerker, A Rothhaas, T Finteis, J Schmeck.   

Abstract

BACKGROUND AND
OBJECTIVE: ProSeal Laryngeal Mask Airway (PLMA) and Laryngeal Tube Suction (LTS), supraglottic airway devices allowing gastric drainage, were compared in this prospective, randomized study for airway management under conditions with elevated intra-abdominal pressure induced by capnoperitoneum.
METHODS: Fifty patients undergoing elective gynaecological laparoscopic surgery were randomized to two groups of 25 each. After induction of general anaesthesia, devices were inserted, correct placement was verified, airway leak pressure was measured, and a gastric tube was inserted. Ease of insertion, quality of airway seal, risk of gastric insufflation and patient comfort were investigated.
RESULTS: There were no differences in patient characteristics data for both groups. First-time insertion success rates were comparable for both groups: 92%--first attempt, 8%--second attempt for PLMA and LTS. Time until delivery of the first tidal volume for PLMA and LTS was 23.2 +/- 6.1 and 23.5 +/- 6.6s, airway leak pressure was 45.4 +/- 4.9 cmH2O and 45.6 +/- 6.7 cmH2O with cuff pressures adjusted to 60 cmH2O. No gastric insufflation, gas loss or signs of regurgitation were detected. Placement of a gastric tube was successful in all patients. Patients were questioned for sore throat and dysphagia after removal of devices. Sore throat was stated in 1%/0% (PLMA) and 8%/4% (LTS) after 6/24 h, dysphagia in 4%/4% (PLMA) and 12%/4% (LTS).
CONCLUSIONS: Both devices provide a secure airway even under conditions of elevated intra-abdominal pressure. In this pilot study, no differences concerning handling or quality of airway seal were detected between PLMA and LTS.

Entities:  

Mesh:

Year:  2005        PMID: 15816590     DOI: 10.1017/s0265021505000220

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  11 in total

1.  [Airway leak pressure of the ProSeal laryngeal mask airway. Comparison with and without a gastric tube placed through the drain-tube].

Authors:  C Freisburger; K Goldmann
Journal:  Anaesthesist       Date:  2006-12       Impact factor: 1.041

Review 2.  [Second generation laryngeal masks : expanded indications].

Authors:  A Timmermann; E A Nickel; F Pühringer
Journal:  Anaesthesist       Date:  2015-01       Impact factor: 1.041

3.  Effect of Pneumoperitoneum and Lateral Position on Oropharyngeal Seal Pressures of Proseal LMA in Laparoscopic Urological Procedures.

Authors:  Preeti Rustagi; Geeta A Patkar; Anil Kumar Ourasang; Bharati A Tendolkar
Journal:  J Clin Diagn Res       Date:  2017-02-01

4.  [Comparison between the laryngeal tubus S and endotracheal intubation. Simulation of securing the airway in an emergency situation].

Authors:  A Thierbach; T Piepho; B Kleine-Weischede; G Haag; M Maybauer; C Werner
Journal:  Anaesthesist       Date:  2006-02       Impact factor: 1.041

5.  [Reduction in no flow time using a laryngeal tube: comparison to bag-mask ventilation].

Authors:  C H R Wiese; J Bahr; A Bergmann; I Bergmann; U Bartels; B M Graf
Journal:  Anaesthesist       Date:  2008-06       Impact factor: 1.041

6.  Techniques for the insertion of the ProSeal laryngeal mask airway: comparison of the Foley airway stylet tool with the introducer tool in a prospective, randomized study.

Authors:  Mao-Kai Chen; Hung-Te Hsu; I-Cheng Lu; Chih-Kai Shih; Ya-Chun Shen; Kuang-Yi Tseng; Kuang-I Cheng
Journal:  BMC Anesthesiol       Date:  2014-11-18       Impact factor: 2.217

Review 7.  Insertion Success of the Laryngeal Tube in Emergency Airway Management.

Authors:  Michael Bernhard; André Gries; Alexandra Ramshorn-Zimmer; Volker Wenzel; Bjoern Hossfeld
Journal:  Biomed Res Int       Date:  2016-08-24       Impact factor: 3.411

Review 8.  Complications Associated with the Use of Supraglottic Airway Devices in Perioperative Medicine.

Authors:  Pavel Michalek; William Donaldson; Eliska Vobrubova; Marek Hakl
Journal:  Biomed Res Int       Date:  2015-12-13       Impact factor: 3.411

Review 9.  Comparison between supraglottic airway devices and endotracheal tubes in patients undergoing laparoscopic surgery: A systematic review and meta-analysis.

Authors:  Sun Kyung Park; Geum Ko; Geun Joo Choi; Eun Jin Ahn; Hyun Kang
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

10.  Comparison of Propofol and Ketamine-Propofol Mixture (Ketofol) on Laryngeal Tube-Suction II Conditions and Hemodynamics: A Randomized, Prospective, Double-Blind Trial.

Authors:  Ulku Ozgul; Zekine Begec; Kalender Karahan; Mehmet Ali Erdogan; Mustafa Said Aydogan; Cemil Colak; Mahmut Durmus; M Ozcan Ersoy
Journal:  Curr Ther Res Clin Exp       Date:  2013-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.