Technical considerations for implementation of x-ray CT polymer gel dosimetry.

M Hilts1, A Jirasek, C Duzenli.   

Abstract

Gel dosimetry is the most promising 3D dosimetry technique in current radiation therapy practice. X-ray CT has been shown to be a feasible method of reading out polymer gel dosimeters and, with the high accessibility of CT scanners to cancer hospitals, presents an exciting possibility for clinical implementation of gel dosimetry. In this study we report on technical considerations for implementation of x-ray CT polymer gel dosimetry. Specifically phantom design, CT imaging methods, imaging time requirements and gel dose response are investigated. Where possible, recommendations are made for optimizing parameters to enhance system performance. The dose resolution achievable with an optimized system is calculated given voxel size and imaging time constraints. Results are compared with MRI and optical CT polymer gel dosimetry results available in the literature.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15815093     DOI: 10.1088/0031-9155/50/8/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.

Authors:  H S Sakhalkar; M Oldham
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

2.  An investigation of the accuracy of an IMRT dose distribution using two- and three-dimensional dosimetry techniques.

Authors:  Mark Oldham; Harshad Sakhalkar; Pengyi Guo; John Adamovics
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

Review 3.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

4.  Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes.

Authors:  Homa Hayati; Asghar Mesbahi; Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2015-07-25

5.  Evaluation of targeting errors in ultrasound-assisted radiotherapy.

Authors:  Michael Wang; Robert Rohling; Cheryl Duzenli; Brenda Clark; Neculai Archip
Journal:  Ultrasound Med Biol       Date:  2008-08-23       Impact factor: 2.998

6.  Normoxic polymer gel dosimetry using less toxic monomer of N-isopropyl acrylamide and X-ray computed tomography for radiation therapy applications.

Authors:  Seyed-Mostafa Ghavami; Asghar Mesbahi; Ismaeel Pesianian; Abbas Shafaee; Mohammad-Reza Aliparasti
Journal:  Rep Pract Oncol Radiother       Date:  2010-11-04

7.  Optimization of the imaging protocol of an X-ray CT scanner for evaluation of normoxic polymer gel dosimeters.

Authors:  Brindha Subramanian; Paul B Ravindran; Clive Baldock
Journal:  J Med Phys       Date:  2006-04

Review 8.  A Review of PRESAGE Radiochromic Polymer and the Compositions for Application in Radiotherapy Dosimetry.

Authors:  Muhammad Zamir Mohyedin; Hafiz Mohd Zin; Mohd Zulfadli Adenan; Ahmad Taufek Abdul Rahman
Journal:  Polymers (Basel)       Date:  2022-07-16       Impact factor: 4.967

Review 9.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  9 in total