Accuracy of temperature measurement in the cardiopulmonary bypass circuit.

Richard F Newland1, Andrew J Sanderson, Robert A Baker.   

Abstract

Oxygenator arterial outlet blood temperature is routinely measured in the cardiopulmonary bypass (CPB) circuit as a surrogate for the temperature of the arterial blood delivered to sensitive organs such as the brain. The aim of this study was to evaluate the accuracy of the temperature thermistors used in the Terumo Capiox SX25 oxygenator and to compare the temperature measured at the outlet of the oxygenator using the Capiox CX*TL Luer Thermistor with temperatures measured at distal sites. Five experimental stages were performed in vitro to achieve this aim. Under our experimental conditions, the luer thermistors accurately measured the temperature as referenced by a precision thermometer. In the CPB circuit, the difference between arterial outlet and reference thermometer temperature varied with outlet temperature over-reading at low temperatures and under reading at high temperatures. There was negligible heat loss (-0.4+/-0.1degrees C) measured at 4.5 m from the arterial outlet. The Terumo Capiox CX*TL Luer Thermistor is an accurate and reliable instrument for measuring temperature when incorporated into the Capiox Oxygenator. The accuracy in the measurement of temperature using these thermistors is affected by the thermistor immersion depth. Under reading of the arterial blood temperature by approximately 0.5 degrees C should be considered at normothermic temperatures, to avoid exceeding the maximum arterial blood temperature as described by institutional protocols. The accuracy of blood temperature measurements should be considered for all oxygenator arterial outlet temperature probes.

Mesh:

Year:  2005        PMID: 15804154      PMCID: PMC4680800     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  7 in total

1.  Clinical evaluation of cerebral oxygen balance during cardiopulmonary bypass: on-line continuous monitoring of jugular venous oxyhemoglobin saturation.

Authors:  T Nakajima; M Kuro; Y Hayashi; K Kitaguchi; O Uchida; O Takaki
Journal:  Anesth Analg       Date:  1992-05       Impact factor: 5.108

2.  Warming during cardiopulmonary bypass is associated with jugular bulb desaturation.

Authors:  N D Croughwell; P Frasco; J A Blumenthal; B J Leone; W D White; J G Reves
Journal:  Ann Thorac Surg       Date:  1992-05       Impact factor: 4.330

3.  Cerebral oxygenation during warming after cardiopulmonary bypass.

Authors:  K J Sapire; S P Gopinath; G Farhat; D R Thakar; A Gabrielli; J W Jones; C S Robertson; B Chance
Journal:  Crit Care Med       Date:  1997-10       Impact factor: 7.598

4.  Cerebral hyperthermia during cardiopulmonary bypass in adults.

Authors:  D J Cook; T A Orszulak; R C Daly; D A Buda
Journal:  J Thorac Cardiovasc Surg       Date:  1996-01       Impact factor: 5.209

Review 5.  Temperature modulation of ischemic brain injury--a synthesis of recent advances.

Authors:  M D Ginsberg; M Y Globus; W D Dietrich; R Busto
Journal:  Prog Brain Res       Date:  1993       Impact factor: 2.453

6.  Differential age effects of mean arterial pressure and rewarming on cognitive dysfunction after cardiac surgery.

Authors:  M F Newman; D Kramer; N D Croughwell; I Sanderson; J A Blumenthal; W D White; L R Smith; E A Towner; J G Reves
Journal:  Anesth Analg       Date:  1995-08       Impact factor: 5.108

7.  Jugular bulb saturation and cognitive dysfunction after cardiopulmonary bypass.

Authors:  N D Croughwell; M F Newman; J A Blumenthal; W D White; J B Lewis; P E Frasco; L R Smith; E A Thyrum; B J Hurwitz; B J Leone
Journal:  Ann Thorac Surg       Date:  1994-12       Impact factor: 4.330

  7 in total
  4 in total

1.  Developing a benchmarking process in perfusion: a report of the Perfusion Downunder Collaboration.

Authors:  Robert A Baker; Richard F Newland; Carmel Fenton; Michael McDonald; Timothy W Willcox; Alan F Merry
Journal:  J Extra Corpor Technol       Date:  2012-03

2.  Oxygenator safety evaluation: a focus on connection grip strength and arterial temperature measurement accuracy.

Authors:  Richard F Newland; Robert A Baker; Andrew J Sanderson; Sigrid C Tuble; Phil J Tully
Journal:  J Extra Corpor Technol       Date:  2012-06

3.  Brachial arterial temperature as an indicator of core temperature: proof of concept and potential applications.

Authors:  Matthew D M Pawley; Paul Martinsen; Simon J Mitchell; James F Cheeseman; Alan F Merry; Timothy Willcox; Robert Grieve; Parma Nand; Elaine Davies; Guy R Warman
Journal:  J Extra Corpor Technol       Date:  2013-06

4.  The Society of Thoracic Surgeons, The Society of Cardiovascular Anesthesiologists, and The American Society of ExtraCorporeal Technology: Clinical Practice Guidelines for Cardiopulmonary Bypass--Temperature Management during Cardiopulmonary Bypass.

Authors:  Richard Engelman; Robert A Baker; Donald S Likosky; Alina Grigore; Timothy A Dickinson; Linda Shore-Lesserson; John W Hammon
Journal:  J Extra Corpor Technol       Date:  2015-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.