Literature DB >> 15801312

Harmonic chirp imaging method for ultrasound contrast agent.

Jerome M G Borsboom1, Chien Ting Chin, Ayache Bouakaz, Michel Versluis, Nico de Jong.   

Abstract

Coded excitation is currently used in medical ultrasound to increase signal-to-noise ratio (SNR) and penetration depth. We propose a chirp excitation method for contrast agents using the second harmonic component of the response. This method is based on a compression filter that selectively compresses and extracts the second harmonic component from the received echo signal. Simulations have shown a clear increase in response for chirp excitation over pulse excitation with the same peak amplitude. This was confirmed by two-dimensional (2-D) optical observations of bubble response with a fast framing camera. To evaluate the harmonic compression method, we applied it to simulated bubble echoes, to measured propagation harmonics, and to B-mode scans of a flow phantom and compared it to regular pulse excitation imaging. An increase of approximately 10 dB in SNR was found for chirp excitation. The compression method was found to perform well in terms of resolution. Axial resolution was in all cases within 10% of the axial resolution from pulse excitation. Range side-lobe levels were 30 dB below the main lobe for the simulated bubble echoes and measured propagation harmonics. However, side-lobes were visible in the B-mode contrast images.

Mesh:

Substances:

Year:  2005        PMID: 15801312     DOI: 10.1109/tuffc.2005.1406550

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  11 in total

1.  Improving the sensitivity of high-frequency subharmonic imaging with coded excitation: a feasibility study.

Authors:  Himanshu Shekhar; Marvin M Doyley
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Observation of contrast agent response to chirp insonation with a simultaneous optical-acoustical system.

Authors:  Yang Sun; Shukui Zhao; Paul A Dayton; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

3.  The response of phospholipid-encapsulated microbubbles to chirp-coded excitation: implications for high-frequency nonlinear imaging.

Authors:  Himanshu Shekhar; Marvin M Doyley
Journal:  J Acoust Soc Am       Date:  2013-05       Impact factor: 1.840

4.  Coded Spectral Doppler Imaging: From Simulation to Real-Time Processing.

Authors:  Alessandro Ramalli; Enrico Boni; Alessandro Dallai; Francesco Guidi; Stefano Ricci; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-05-26       Impact factor: 2.725

5.  Pulse inversion chirp coded tissue harmonic imaging (PI-CTHI) of Zebrafish heart using high frame rate ultrasound biomicroscopy.

Authors:  Jinhyoung Park; Ying Huang; Ruimin Chen; Jungwoo Lee; Thomas M Cummins; Qifa Zhou; Ching-Ling Lien; K K Shung
Journal:  Ann Biomed Eng       Date:  2012-08-29       Impact factor: 3.934

6.  Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array.

Authors:  Anthony Novell; Christopher B Arena; Sandeep Kasoji; Paul A Dayton
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

Review 7.  Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering.

Authors:  Shengping Qin; Charles F Caskey; Katherine W Ferrara
Journal:  Phys Med Biol       Date:  2009-02-19       Impact factor: 3.609

8.  Molecular Acoustic Angiography: A New Technique for High-resolution Superharmonic Ultrasound Molecular Imaging.

Authors:  Sarah E Shelton; Brooks D Lindsey; James K Tsuruta; F Stuart Foster; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-12-08       Impact factor: 2.998

9.  Frequency-Dependent Spatial Coherence in Conventional and Chirp Transmissions.

Authors:  James Long; Nick Bottenus; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-04-26       Impact factor: 2.725

10.  Optimization of contrast-to-tissue ratio by adaptation of transmitted ternary signal in ultrasound pulse inversion imaging.

Authors:  Sébastien Ménigot; Jean-Marc Girault
Journal:  Comput Math Methods Med       Date:  2013-03-20       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.