Literature DB >> 15800890

Percutaneous closure of an aortic prosthetic paravalvular leak with an Amplatzer duct occluder.

John G Webb1, Gordon E Pate, Brad I Munt.   

Abstract

Following aortic valve replacement, up to 5% of patients may develop clinically significant paravalvular leaks. Reoperation is associated with higher mortality and an excess risk of recurrent paravalvular insufficiency. No specifically designed transcatheter device is available for paravalvular leak repair. We describe in a patient with severe aortic prosthetic paravalvular leak the use of an Amplatzer duct occluder device resulting in effective closure and symptomatic improvement. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 15800890     DOI: 10.1002/ccd.20337

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  6 in total

1.  In Vitro and Ex Vivo Hemodynamic Testing of an Innovative Occluder for Paravalvular Leak After Transcather Aortic Valve Implantation.

Authors:  Paolo Peruzzo; Gaetano Burriesci; Francesca Maria Susin; Andrea Colli
Journal:  J Cardiovasc Transl Res       Date:  2019-07-30       Impact factor: 4.132

2.  Unconventional uses of septal occluder devices: Our experience reviewed.

Authors:  Neeraj Awasthy; Munesh Tomar; S Radhakrishnan; Savitri Shrivastava
Journal:  Indian Heart J       Date:  2015-05-14

3.  Closure of a para-valvular aortic leak: with the use of 2 AMPLATZER devices and real-time 2- and 3-dimensional transesophageal echocardiography.

Authors:  Kurt S Hoffmayer; Christian Zellner; Damon M Kwan; Suma Konety; Elyse Foster; Phillip Moore; Yerem Yeghiazarians
Journal:  Tex Heart Inst J       Date:  2011

4.  Interventional closure of two fistulas after aortic valve surgery.

Authors:  Robert Dalla Pozza; R Kozlik-Feldmann; T-P Le; C Schmitz; R Sodian; B Reichart; Heinrich Netz
Journal:  Clin Res Cardiol       Date:  2009-04-09       Impact factor: 5.460

5.  Percutaneous Closure of an Aortic Prosthetic Paravalvular Leak with Device in a Patient Presenting with Heart Failure.

Authors:  Altug Osken; Ercan Aydin; Ramazan Akdemir; Huseyin Gunduz
Journal:  Heart Views       Date:  2015 Apr-Jun

6.  Transcatheter closures for fistula tract and paravalvular leak after mitral valve replacement and tricuspid annuloplasty.

Authors:  Sang Yong Om; Gyung Min Park; Jin Yong Kim; Yong Hoon Yoon; Sinwon Lee; Young-Hak Kim; Jae-Kwan Song
Journal:  Korean Circ J       Date:  2014-01-14       Impact factor: 3.243

  6 in total